Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 60
CR_PFAIL03 Command, CR_PFAIL04 Command, CR_PFAIL05 Command, CR_PFAIL06 Command
View all Canon LV-7575 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
LV-7575 Expand Serial Command Functional Specifications 9.12.10 CR_PFAIL03 Command Command "CR_PFAIL03" [CR] Details Get the item name and status of Power Failure No.3 Acceptable "000_%1_%2" [CR] Response %1 ------ Item name of Power Failure (16-byte fixed length) %1 %2 ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 9.12.11 CR_PFAIL04 Command Command "CR_PFAIL04" [CR] Details Get the item name and status of Power Failure No.4 Acceptable "000_%1_%2" [CR] Response %1 ------ Item name of Power Failure (16-byte fixed length) %1 %2 ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 9.12.12 CR_PFAIL05 Command Command "CR_PFAIL05" [CR] Details Get the item name and status of Power Failure No.5 Acceptable "000_%1_%2" [CR] Response %1 ------ Item name of Power Failure (16-byte fixed length) %1 %2 ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 9.12.13 CR_PFAIL06 Command Command "CR_PFAIL06" [CR] Details Get the item name and status of Power Failure No.6 Acceptable "000_%1_%2" [CR] Response %1 ------ Item name of Power Failure (16-byte fixed length) %1 %2 ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 60/71