Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 59

CR_ALLPFAIL Command, CR_HMPFAIL Command, CR_PFAIL01 Command, CR_PFAIL02 Command

Page 59 highlights

LV-7575 Expand Serial Command Functional Specifications 9.12.6 CR_ALLPFAIL Command Command "CR_ALLPFAIL" [CR] Details Get all the information on Power Failure Return all the responses of "CR_PFAIL01" - "PFAIL50" at once Therefore it consists of 1200 (24 bytes x 50) bytes totally Response Acceptable %1 - %100 "000_%1_%2" [CR] "000_%3_%4" [CR] "000_%5_%6" [CR] : : "000_%97_%98" [CR] "000_%99_%100" [CR] (Send all 50 blocks above at one time) %1, %3, •••%99 (Odd number) ------ Item name of Power Failure (16-byte fixed length) %2, %4, •••%100 (Even number) ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 9.12.7 CR_HMPFAIL Command Command "CR_ HMPFAIL" [CR] Details Get total number of detectable Power Failure Acceptable "000_%1" [CR] Response %1 "000 - 050" Unacceptable "Error Code" [CR] 9.12.8 CR_PFAIL01 Command Command "CR_PFAIL01" [CR] Details Get item name and status of Power Failure No.1 Acceptable "000_%1_%2" [CR] Response %1 ------ Item name of Power Failure (16-byte fixed length) %1 %2 ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 9.12.9 CR_PFAIL02 Command Command "CR_PFAIL02" [CR] Details Get the item name and status of Power Failure No.2 Acceptable "000_%1_%2" [CR] Response %1 ------ Item name of Power Failure (16-byte fixed length) %1 %2 ------ Power status (2-byte fixed length) Power is failed: "NG" Power status is normal: "OK" Unacceptable "Error Code" [CR] 59/71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

LV-7575 Expand Serial Command Functional Specifications
59/71
9.12.6
CR_ALLPFAIL Command
Command
“CR_ALLPFAIL” [CR]
Details
Get all the information on Power Failure
Return all the responses of “CR_PFAIL01” – “PFAIL50” at once
Therefore it consists of 1200 (24 bytes x 50) bytes totally
Acceptable
“000_%1_%2” [CR]
“000_%3_%4” [CR]
“000_%5_%6” [CR]
:
:
“000_%97_%98” [CR]
“000_%99_%100” [CR]
(Send all 50 blocks above at one time)
%1 - %100
%1, %3, •••%99 (Odd number)
------ Item name of Power Failure (16-byte fixed length)
%2, %4, •••%100 (Even number)
------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable
“Error Code” [CR]
9.12.7
CR_HMPFAIL Command
Command
“CR_ HMPFAIL” [CR]
Details
Get total number of detectable Power Failure
Acceptable
“000_%1” [CR]
%1
“000 – 050”
Response
Unacceptable
“Error Code” [CR]
9.12.8
CR_PFAIL01 Command
Command
“CR_PFAIL01” [CR]
Details
Get item name and status of Power Failure No.1
Acceptable
“000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable
“Error Code” [CR]
9.12.9
CR_PFAIL02 Command
Command
“CR_PFAIL02” [CR]
Details
Get the item name and status of Power Failure No.2
Acceptable
“000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable
“Error Code” [CR]