Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 70
CR_TEMPFAIL Command
View all Canon LV-7575 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
LV-7575 Expand Serial Command Functional Specifications 9.12.58 CR_TEMPFAIL Command Command "CR_TEMPFAIL" [CR] Details Get the temperature inside a projector when abnormal temperature status occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable "000_%1_%2_%3" [CR] Response %1,%2,%3 %1 Sensor 1 temp. %2 Sensor 2 temp. %3 Sensor 3 temp. e.g. "_31.5F" "_" indicates a space. When the temperature goes under 0, the first character is "-", not a space, as in "-05.5F". With more than one temperature sensors installed, projector returns responses in a row. e.g. "_31.5F _ _35.2S _ _38.0W " [CR] The first data indicates sensor 1 data, then one space, and sensor 2 data. Last character in each data indicates the sensor's status. "F Exceeding critical temp. (abnormal temp.) "W Approaching critical temp. (Warning temp.) "S Sensor temp. is safe (Safe temp.) "N Sensor detects no critical temp. "E Unable to return the temp. data The example 1 shows that sensor 1 indicates 31.5 degrees and the temperature is abnormal, sensor 2 indicates 35.2 degrees and the temperature is safe, sensor 3 indicates 38.0 degrees and the temperature is approaching critical state. When the temperature is safe, all data is represented as "_00.0S". When the projector is reset, "_00.0S" is set, and every time abnormal temperature occurs, it renews the data and returns it. In short, it only returns the renewed data of the latest abnormal temperature and the previous data is deleted. Unacceptable "?" [CR] 70/71