Canon LV-7575 LV-7575 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS - Page 58

CR_PRESSURE Command, CR_SIGNAL Command, CR_VMUTE Command, CR_FREEZE Command

Page 58 highlights

LV-7575 Expand Serial Command Functional Specifications Unacceptable "Error Code" [CR] 9.12.2 CR_PRESSURE Command Command "CR_PRESSURE" [CR] Details Get value from Air Pressure sensor. Fllowing is the formula to work out Air Pressure from the given value ("Vn" represents the value): Air Pressure (hPa) = 5*Vn / 1024 - 0.204 / 0.00459 + 150 Obtains accuracy of +/- 2% Response Acceptable %1 "000_%1" [CR] "0000" - "1023" Unacceptable "Error Code" [CR] 9.12.3 CR_SIGNAL Command Command "CR_SIGNAL" [CR] Details Get status whether there is any signal or not. Acceptable "000_%1" [CR] Response %1 "ON There is signal "OFF There is no signal Unacceptable "?" [CR] 9.12.4 CR_VMUTE Command Command "CR_VMUTE" [CR] Details Get setting status of No Show. Acceptable "000_%1" [CR] Response %1 "ON No show is enabled "OFF No show is disabled Unacceptable "?" [CR] 9.12.5 CR_FREEZE Command Command "CR_FREEZE" [CR] Details Get setting status of Freeze. Acceptable "000_%1" [CR] Response %1 "ON Freeze is enabled "OFF Freeze is disabled Unacceptable "?" [CR] 58/71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

LV-7575 Expand Serial Command Functional Specifications
58/71
Unacceptable
“Error Code” [CR]
9.12.2
CR_PRESSURE Command
Command
“CR_PRESSURE” [CR]
Details
Get value from Air Pressure sensor.
Fllowing is the formula to work out Air Pressure from the given value (“Vn”
represents the value):
Air Pressure (hPa) =
5*Vn / 1024 – 0.204
/ 0.00459 + 150
Obtains accuracy of +/- 2%
Acceptable
“000_%1” [CR]
%1
“0000” – “1023”
Response
Unacceptable
“Error Code” [CR]
9.12.3
CR_SIGNAL Command
Command
“CR_SIGNAL” [CR]
Details
Get status whether there is any signal or not.
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- There is signal
“OFF” ------------------------- There is no signal
Response
Unacceptable
“?” [CR]
9.12.4
CR_VMUTE Command
Command
“CR_VMUTE” [CR]
Details
Get setting status of No Show.
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- No show is enabled
“OFF” ------------------------ No show is disabled
Response
Unacceptable
“?” [CR]
9.12.5
CR_FREEZE Command
Command
“CR_FREEZE” [CR]
Details
Get setting status of Freeze.
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------------- Freeze is enabled
“OFF” -------------------------- Freeze is disabled
Response
Unacceptable
“?” [CR]