CR_PRESSURE Command, CR_SIGNAL Command, CR_VMUTE Command, CR_FREEZE Command
View all Canon LV-7575 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
LV-7575 Expand Serial Command Functional Specifications Unacceptable "Error Code" [CR] 9.12.2 CR_PRESSURE Command Command "CR_PRESSURE" [CR] Details Get value from Air Pressure sensor. Fllowing is the formula to work out Air Pressure from the given value ("Vn" represents the value): Air Pressure (hPa) = 5*Vn / 1024 - 0.204 / 0.00459 + 150 Obtains accuracy of +/- 2% Response Acceptable %1 "000_%1" [CR] "0000" - "1023" Unacceptable "Error Code" [CR] 9.12.3 CR_SIGNAL Command Command "CR_SIGNAL" [CR] Details Get status whether there is any signal or not. Acceptable "000_%1" [CR] Response %1 "ON There is signal "OFF There is no signal Unacceptable "?" [CR] 9.12.4 CR_VMUTE Command Command "CR_VMUTE" [CR] Details Get setting status of No Show. Acceptable "000_%1" [CR] Response %1 "ON No show is enabled "OFF No show is disabled Unacceptable "?" [CR] 9.12.5 CR_FREEZE Command Command "CR_FREEZE" [CR] Details Get setting status of Freeze. Acceptable "000_%1" [CR] Response %1 "ON Freeze is enabled "OFF Freeze is disabled Unacceptable "?" [CR] 58/71