Cisco SFS-7012 User Guide - Page 101

Technical Specifications

Page 101 highlights

A A P P E N D I X Technical Specifications Table A-1 SFS 7012 Technical Specifications Switch Physical Dimensions Weight Cooling Environmental Power Supply Certification Marks • 7U high (24.5") • 19" rack mount (17.32" wide) • 25 3/4" deep (without cables) • 100 lb. (including power supplies) • Air cooled with 4 hot plug fan trays • Two fans per tray, 60mm, 12VDC • Front-to-back airflow • Active thermal performance monitoring switch board via IBML links • Operating temperature: 50° - 104°F (5° - 40°C) at sea level, altitude derating 2°F (1°C) per 300m to 2,000m • Non-operating temperature: -35°C to 65°C • Relative humidity (non-condensing): operating 5% - 85%; non-operating 5% - 90% • Self-contained thermal management • Up to six redundant, hot plug supplies • 90/264 VAC operation • 350W max power per supply • Input: • 90-264V AC, 47-63Hz, 1 Phase, 6.5A max current at 115VAC • Inrush Current: • 15A @ 115VAC (25°C cold start) 30A @ 230VAC (25°C cold start) • Power Factor 0.95 • Two IEC 320 connectors for independent AC inputs • UL, CSA, CE, VCCI, GS, FCC Class B, IC Class B, ICES - 003 OL-8787-04 Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide 83

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

83
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-04
APPENDIX
A
Technical Specifications
Table A-1
SFS 7012 Technical Specifications
Switch Physical
Dimensions
7U high (24.5”)
19" rack mount (17.32" wide)
25 3/4" deep (without cables)
Weight
100 lb. (including power supplies)
Cooling
Air cooled with 4 hot plug fan trays
Two fans per tray, 60mm, 12VDC
Front-to-back airflow
Active thermal performance monitoring switch board
via IBML links
Environmental
Operating temperature: 50° - 104°F (5° - 40°C) at sea
level, altitude derating 2
°
F (1
°
C) per 300m to 2,000m
Non-operating temperature: -35
°
C to 65
°
C
Relative humidity (non-condensing): operating 5% –
85%; non-operating 5% – 90%
Self-contained thermal management
Power Supply
Up to six redundant, hot plug supplies
90/264 VAC operation
350W max power per supply
Input:
90–264V AC, 47–63Hz, 1 Phase, 6.5A max current at
115VAC
Inrush Current:
15A @ 115VAC (25
°
C cold start)
30A @ 230VAC (25
°
C cold start)
Power Factor 0.95
Two IEC 320 connectors for independent AC inputs
Certification Marks
UL, CSA, CE, VCCI, GS, FCC Class B, IC Class B,
ICES - 003