Cisco SFS-7012 User Guide - Page 114

Problem, Fix, OOB Ethernet RJ45 Port, SFS 7012 Leaf Module IB Ports

Page 114 highlights

Fan Problem Red LED is lit Fan not running Appendix Fix Call Tech Support Ensure fan is seated properly. If fan continues to be inoperable, call Tech Support OOB Ethernet RJ45 Port Problem Fix The SFS 7012 Ethernet Port(s) have a Ensure that the cable is a straight-through RJ45 Cable with a Noise Problem: Cat 5 cable (not a crossover cable). This problem would occur if there is a RJ45 cable that has poor shielding or contact of pins. If using a straight-through cable and still experiencing this problem: Test with a known good cable. Absence of Ethernet link and/or Ensure that the Ethernet cable is Cat 5E or intermittent Ethernet connectivity. Cat 6 certified. SFS 7012 Leaf Module IB Ports Problem No LED Bad IB Cable Fix LED may be bad if IB Link (A and B) LEDs are lit, and the ATTN and/or STAT is not. If the QUAL LED is not lit: Test with a known good IB cable. Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide 96 OL-8787-04

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

96
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-04
Appendix
Fan
OOB Ethernet RJ45 Port
SFS 7012 Leaf Module IB Ports
Problem
Fix
Red LED is lit
Call Tech Support
Fan not running
Ensure fan is seated properly.
If fan continues to be inoperable, call
Tech Support
Problem
Fix
The SFS 7012 Ethernet Port(s) have a
RJ45 Cable with a Noise Problem:
This problem would occur if there is a
RJ45 cable that has poor shielding or
contact of pins.
Ensure that the cable is a straight-through
Cat 5 cable (not a crossover cable).
If using a straight-through cable and still
experiencing this problem:
Test with a known good cable.
Absence of Ethernet link and/or
intermittent Ethernet connectivity.
Ensure that the Ethernet cable is Cat 5E or
Cat 6 certified.
Problem
Fix
No LED
LED may be bad if IB Link (A and B)
LEDs are lit, and the ATTN and/or STAT
is not.
Bad IB Cable
If the QUAL LED is not lit:
Test with a known good IB cable.