Cisco SFS-7012 User Guide - Page 53

SFS 7012 Leaf and Spine Module LEDs, Subnet Manager Agent SMA LED, RJ45 LEDs, Fan LEDs

Page 53 highlights

Chapter The chassis status LED is off when: • There are no functional power supplies present. • There are no management cards in the system • AC power has been removed from the system. Subnet Manager Agent (SMA) LED There is a single SMA LED associated with the system. This LED is Blue if any external InfiniBand links have been established. If no external IB links have been established, the LED if off. RJ45 LEDs The SFS 7012 RJ45 connector has two LEDs, Act and 100. The 100 LED is Green when a 100Mbps link is connected. The Act LED is Green when an Ethernet link has been established, and blinking when the link is active. Fan LEDs Fan LEDs indicate the following status(es): • Green indicates that the fan is functioning properly. • Amber indicates that the following warning condition exists: • A single fan rotation failure at less than 4000 RPM or greater than 10950 RPM. • Red indicates a possible problem, including: - The fan tray is not responding to commands for configuration and temperature-related operations. - A fan is not responding to commands for temperature and speed related operations. - The fan speed has fallen below the minimum allowed RPM for a fan. Power Supply LEDs Each SFS 7012 power supply has two LEDs: DC OK and AC OK. Following are the statuses for each. DC OK - Green indicates that DC power is normal. - Off indicates a DC power failure or no DC power is present. AC OK - Amber indicates that AC power is normal. - Off indicates a AC power failure or no AC power is present. SFS 7012 Leaf and Spine Module LEDs Leaf Module IB Port LEDs Each SFS 7012 leaf module port has a Blue IB link status LED that provide the following indications: • On - the logical link is up (port is in the Active state). • Slow Blink - the physical link is up (port is in the Initialization state). OL-8787-04 Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

35
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-04
Chapter
The chassis status LED is
off
when:
There are no functional power supplies present.
There are no management cards in the system
AC power has been removed from the system.
Subnet Manager Agent (SMA) LED
There is a single SMA LED associated with the system. This LED is
Blue
if any external InfiniBand
links have been established. If no external IB links have been established, the LED if
off
.
RJ45 LEDs
The SFS 7012 RJ45 connector has two LEDs,
Act
and
100
. The
100
LED is
Green
when a 100Mbps
link is connected. The
Act
LED is
Green
when an Ethernet link has been established, and blinking when
the link is active.
Fan LEDs
Fan LEDs indicate the following status(es):
Green
indicates that the fan is functioning properly.
Amber
indicates that the following warning condition exists:
A single fan rotation failure at less than 4000 RPM or greater than 10950 RPM.
Red
indicates a possible problem, including:
The fan tray is not responding to commands for configuration and temperature-related
operations.
A fan is not responding to commands for temperature and speed related operations.
The fan speed has fallen below the minimum allowed RPM for a fan.
Power Supply LEDs
Each SFS 7012 power supply has two LEDs: DC OK and AC OK. Following are the statuses for each.
DC OK
Green
indicates that DC power is normal.
Off
indicates a DC power failure or no DC power is present.
AC OK
Amber
indicates that AC power is normal.
Off
indicates a AC power failure or no AC power is present.
SFS 7012 Leaf and Spine Module LEDs
Leaf Module IB Port LEDs
Each SFS 7012 leaf module port has a
Blue
IB link status LED that provide the following indications:
On
- the logical link is up (port is in the Active state).
Slow Blink
- the physical link is up (port is in the Initialization state).