Compaq Portable 486 Compaq Portable 486c Personal Computer Maintenance and Ser - Page 38
Error Correction Code error, Failed correctable Error - 66
View all Compaq Portable 486 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
1719 - 47 Failed to park heads 1719 - 48 Failed to move disk table to RAM Error Recommended Code Description Action 1719 - 49 Failed to read media in The following steps apply file write test to error codes 1700 - xx through 1719 - xx: 1719 - 50 Failed file I/O write test 1. Replace the fixed disk drive and retest. 1719 - 51 Failed file I/O read test 2. Replace the power distribution board 1719 - 52 Failed file I/O compare test and retest. 3. Replace the I/O board 1719 - 53 Failed drive/head and retest. register test 1719 - 54 Failed digital input register test 1719 - 55 Failed cylinder 1 1719 - 56 Fixed disk drive controller RAM diagnostics failed 1719 - 57 Fixed disk drive controller to drive test failed 1719 - 58 Failed to write sector buffer 1719 - 59 Failed to read sector buffer 1719 - 60 Failed to compare sector buffer 1719 - 61 Failed uncorrectable Error Correction Code error Error Recommended Code Description Action 1719 - 62 Failed correctable Error The following steps apply Correction Code error to error codes 1700 - xx through 1719 - xx: 1719 - 63 Failed soft error rate 1. Replace the fixed disk and retest. 1719 - 65 Exceeded maximum 2. Replace the power bad sector per track distribution board and retest. 1719 - 66 Failed initial drive 3. Replace the I/O board parameter and retest. 1719 - 67 Failed to write long