Error Code, Audible Beeps, L=Long, S=Short, Probable Source of Problem, Recommended Action - processor incorrect slot
![]() |
View all Compaq ProLiant 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
3-6 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 201-Memory Error None RAM failure. Recommended Action Run Diagnostics. Replace failed assembly as indicated. 203-Memory Address Error None RAM failure. Run Diagnostics. Replace failed assembly as indicated. 205-Cache Memory Error None Cache memory error. Replace the processor board in the slot indicated. 205-Option Cache Memory Error None Option cache memory error. Replace the option cache board. 206-Cache Controller Error None Cache controller failure. Run Diagnostics. Replace failed assembly as indicated. 207-Invalid Memory Configuration Check DIMM [SIMM] Installation None Memory module installed incorrectly. Verify placement of memory modules. 208-Invalid Memory Speed - Check DIMM [SIMM] Installation 1L, 1S The speed of the memory is too slow, where: xx00 = expansion board SIMMs are too slow, or 00yy = system board SIMMs are too slow. xx and yy have corresponding bit set. The speed of the memory modules must be 60 ns. Verify the speed of the memory modules installed and replace. 210- Invalid Memory None Maximum amount of Configuration memory exceeded. Detected. System halted. Verify installed memory does not exceed 1 GB. 211-Cache Switch Set Incorrectly None Switch not set properly during Verify switch settings. installation or upgrade. 212-System Processor Failed/Mapped out 1S Processor in slot x failed. Run Diagnostics and replace failed processor. 213-Cache Size Error None Invalid optional cache size. Replace cache with 256K cache. 213-System Processor Not Installed 1S System processor configured Install processor in the slot indicated or for slot indicated is missing. run the System Configuration Utility to remove the processor from the.CFG file. 214-DC-DC Converter Failed None PowerSafe Module (DC-DC Run Diagnostics. Replace failed Converter) failed. assembly as indicated. Continued
![](/manual_guide/products/compaq-proliant-800-proliant-800-servers-supporting-pentium-ii-processors-100-mhz-bus-maintenance-service-guide-13a6d03/44.png)