Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 45

Run Diagnostics., Replace failed assembly

Page 45 highlights

3-7 POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 301-Keyboard Error None Keyboard failure. Recommended Action Turn off the computer, then reconnect the keyboard. 301-Keyboard Error or None Keyboard failure. Test Fixture Installed Replace the keyboard. ZZ-301-Keyboard Error None Keyboard failure. (ZZ represents 1. A key is stuck. Try to free it. the Keyboard 2. Replace the keyboard. Scan Code.) 303-Keyboard Controller Error None System board, keyboard, or 1. Run Diagnostics. mouse controller failure. 2. Replace failed assembly as indicated. 304-Keyboard or System Unit Error None Keyboard, keyboard cable, or 1. Make sure the keyboard is attached. system board failure. 2. Run Diagnostics to determine which is in error. 3. Replace the part indicated. 40X-Parallel Port X Address Assignment Conflict 2S Both external and internal ports Run the System Configuration Utility are assigned to parallel port X. and correct. 402-Monochrome Adapter Failure 1L, 2S Monochrome display controller. Replace the monochrome display controller. 501-Display Adapter Failure 601-Diskette Controller Error 1L, 2S None Video display controller. Diskette controller circuitry failure. Replace the video board. 1. Make sure the diskette drive cables are attached. 2. Replace the diskette drive and/or cable. 3. Replace the system board. 605-Diskette Drive Type Error 2S Mismatch in drive type. Run the System Configuration Utility to set diskette type correctly. 702-A coprocessor has been detected that was not reported by CMOS None Installed coprocessor not Run the System Configuration Utility configured. and correct. Continued Compaq ProLiant 800 Servers Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

3-7
Compaq ProLiant 800 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long
S=Short
Probable Source of Problem
Recommended Action
301-Keyboard Error
None
Keyboard failure.
Turn off the computer, then reconnect
the keyboard.
301-Keyboard Error or
Test Fixture Installed
None
Keyboard failure.
Replace the keyboard.
ZZ
-301-Keyboard
Error
None
Keyboard failure. (
ZZ
represents
the Keyboard
Scan Code.)
1.
A key is stuck. Try to free it.
2.
Replace the keyboard.
303-Keyboard
Controller Error
None
System board, keyboard, or
mouse controller failure.
1.
Run Diagnostics.
2.
Replace failed assembly as
indicated.
304-Keyboard or
System Unit Error
None
Keyboard, keyboard cable, or
system board failure.
1.
Make sure the keyboard is
attached.
2.
Run Diagnostics to determine
which is in error.
3.
Replace the part indicated.
40X-Parallel Port X
Address Assignment
Conflict
2S
Both external and internal ports
are assigned to parallel port X.
Run the System Configuration Utility
and correct.
402-Monochrome
Adapter Failure
1L, 2S
Monochrome display controller.
Replace the monochrome
display controller.
501-Display Adapter
Failure
1L, 2S
Video display controller.
Replace the video board.
601-Diskette
Controller Error
None
Diskette controller circuitry
failure.
1.
Make sure the diskette drive
cables are attached.
2.
Replace the diskette drive
and/or cable.
3.
Replace the system board.
605-Diskette Drive
Type Error
2S
Mismatch in drive type.
Run the System Configuration Utility to
set diskette type correctly.
702-A coprocessor
has been detected
that was not reported
by CMOS
None
Installed coprocessor not
configured.
Run the System Configuration Utility
and correct.
Continued