Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 63

Hard Drive Test Error Codes, Table 3-11

Page 63 highlights

3-25 Hard Drive Test Error Codes The 1700 series of Diagnostic error codes identifies failures with hard drives, hard drive controller boards, hard drive cabling, and system board functions. If your system uses a drive array controller, see the section for Drive Array Advanced Diagnostics (DAAD). Table 3-11 Hard Drive Test Error Codes Error Code Description 1700-xx 1701-xx 1702-xx 1703-xx 1704-xx 1705-xx 1708-xx 1709-xx 1710-xx 1715-xx 1716-xx 1717-xx 1719-xx 1736-xx 1799-xx Fixed disk ID drive types test failed. Fixed disk format test failed. Fixed disk read test failed. Fixed disk write/read/compare test failed. Fixed disk random seek test failed. Fixed disk controller test failed. Fixed disk format bad track test failed. Fixed disk reset controller test failed. Fixed disk park head test failed. Fixed disk head select test failed. Fixed disk conditional format test failed. Fixed disk ECC* test failed. Fixed disk drive power mode test failed. Drive Monitoring failed. Invalid fixed disk drive type failed. * Error Checking and Correcting Recommended Action 1. Run the System Configuration Utility and verify the drive type. 2. Replace the fixed disk drive signal and 3. Replace the fixed disk drive controller and retest. 4. Replace the fixed disk drive and retest. 5. Replace the system board and retest. Compaq ProLiant 800 Servers Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

3-25
Compaq ProLiant 800 Servers Maintenance and Service Guide
Hard Drive Test Error Codes
The 1700 series of Diagnostic error codes identifies failures with hard drives, hard drive
controller boards, hard drive cabling, and system board functions. If your system uses a drive
array controller, see the section for Drive Array Advanced Diagnostics (DAAD).
Table 3-11
Hard Drive Test Error Codes
Error Code
Description
Recommended Action
1700-xx
1701-xx
1702-xx
1703-xx
1704-xx
1705-xx
1708-xx
1709-xx
1710-xx
1715-xx
1716-xx
1717-xx
1719-xx
1736-xx
1799-xx
Fixed disk ID drive types test failed.
Fixed disk format test failed.
Fixed disk read test failed.
Fixed disk write/read/compare test failed.
Fixed disk random seek test failed.
Fixed disk controller test failed.
Fixed disk format bad track test failed.
Fixed disk reset controller test failed.
Fixed disk park head test failed.
Fixed disk head select test failed.
Fixed disk conditional format test failed.
Fixed disk ECC* test failed.
Fixed disk drive power mode test failed.
Drive Monitoring failed.
Invalid fixed disk drive type failed.
1.
Run the System Configuration Utility and
verify the drive type.
2.
Replace the fixed disk drive signal and
3.
Replace the fixed disk drive controller and
retest.
4.
Replace the fixed disk drive and retest.
5.
Replace the system board and retest.
* Error Checking and Correcting