Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 54
Loss. Select F1 to, Select F2
View all Compaq ProLiant 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
3-16 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1798-Drive Array - None Hard parity error while writing Array Accelerator data to posted-writes memory. Write Error Occurred. Recommended Action Enable Array Accelerator. Array Accelerator is disabled. 1799-Drive Array - None Volume failed due to loss of data Press F1 to continue with logical drives Drive(s) Disabled in posted-writes memory. disabled or F2 to accept data loss and due to Array re-enable logical drive. Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re-enable logical drives. Beeps only: 2 Long + 2 Short 2L, 2S Power is cycled. Temperature too hot. Processor fan not installed or spinning. Check fans. (Run System None A configuration error occurred Press F10 to run System Configuration Configuration Utility - during POST. Utility. F10 key) (RESUME - F1 KEY) None As indicated to continue. Press the F1 key.