Dell Brocade 6510 Fabric OS Command Reference v7.1.0 - Page 117
Backend port credit recovery examples, bottleneckmon --status, bottleneckmon --cfgcredittools
View all Dell Brocade 6510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
bottleneckMon 2 Jan 13 18:54:10 Jan 13 18:54:15 Jan 13 18:54:20 Jan 13 18:54:25 Jan 13 18:54:30 Jan 13 18:54:15 Jan 13 18:54:20 Jan 13 18:54:25 Jan 13 18:54:30 Jan 13 18:54:35 20.00 80.00 0.00 0.00 40.00 To display bottleneck configuration details for the switch: switch:admin> bottleneckmon --status Bottleneck detection - Enabled Switch-wide sub-second latency bottleneck criterion: Time threshold - 0.800 Severity threshold - 50.000 Switch-wide alerting parameters: Alerts - Congestion only Congestion threshold for alert - 0.800 Averaging time for alert - 300 seconds Quiet time for alert - 300 seconds Per-port overrides for sub-second latency bottleneck criterion: Slot Port TimeThresh SevThresh 1 3 0.500 100.000 1 4 0.600 50.000 1 5 0.700 20.000 Per-port overrides for alert parameters: Slot Port Alerts? LatencyThresh CongestionThresh Time(s) QTime(s) 1 1 Y 0.100 0.800 300 300 1 2 C -- 0.800 600 600 1 3 L 0.100 -- 300 300 1 4 N -- -- -- -- Excluded ports: Slot Port ============ 1 2 1 3 1 4 Backend port credit recovery examples To enable backend port credit recovery with the link reset only option and to display the configuration: switch:admin> bottleneckmon --cfgcredittools \ -intport -recover onLrOnly switch:admin> bottleneckmon --showcredittools Internal port credit recovery is Enabled with LrOnly Fabric OS Command Reference 89 53-1002746-01