Dell PowerConnect W-Airwave W-Airwave 7.2 Configuration Guide - Page 79
Profiles > IDS > General, General, Dell PowerConnect W Navigation, pencil, Details
View all Dell PowerConnect W-Airwave manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Rate Thresholds-Defines thresholds assigned to the different frame types for rate anomaly checking. Refer to "Profiles > IDS > Denial of Service > Rate Threshold" on page 84. Impersonation-Configures anomaly settings for impersonation attacks. Refer to "Profiles > IDS > Impersonation" on page 85. Unauthorized Device-Configures detection for unauthorized devices. Also configures rogue AP detection and containment. Refer to "Profiles > IDS > Unauthorized Device" on page 86. 5. Select Add or Save. The added or edited IDS profile appears on the IDS profiles page. Profiles > IDS > General Perform these steps to configure a General IDS profile. 1. Select Profiles > IDS > General in the Dell PowerConnect W Navigation pane. The list of current IDS profiles appears on this page. 2. Select the Add button to create a new General profile, or click the pencil icon next to an existing profile to edit. The Details page appears. Complete the settings as described in Table 27: Table 27 Profiles > IDS > General Profile Settings Field Default Description General Settings Folder Name Top Blank Set the folder with which the profile is associated. The drop-down menu displays all folders available for association with the profile. Enter the name of the profile. Other Settings and AP SNMP User Profiles Stats Update Interval 60 (60-36000 sec) AP Max Unseen Timeout 600 (5-36000 sec) Set the time interval, in seconds, for the AP to update the controller with statistics. NOTE: This setting takes effect only if the Dell PowerConnect W Mobility Manager is configured. Otherwise, statistics update to the controller is disabled. Sets the time, in seconds, after which an AP is aged out. NOTE: This setting requires a minimum of AOS 6.0.0.0. AP Inactivity Timeout 5 (5-36000 sec) STA Max Unseen 600 Timeout (5-36000 sec) Set the time, in seconds, after which an AP is aged out. Sets the time, in seconds, after which a station is aged out. NOTE: This setting requires a minimum of AOS 6.0.0.0. STA Inactivity Timeout 60 (30-36000 sec) Min Potential AP Beacon 25 Rate (0-100%) Min Potential AP Monitor 2 Time (0-36000 sec) Signature Quiet Time (60- 900 360000 sec) Set the time, in seconds, after which a station is aged out. Set the minimum beacon rate acceptable from a potential AP, in percentage of the advertised beacon interval. Set the minimum time, in seconds, a potential AP has to be up before it is classified as a real AP. Set the time to wait, in seconds, after which the check can be resumed when detecting a signature match. Dell PowerConnect W AirWave 7.2 | Configuration Guide Dell PowerConnect W Configuration Reference | 79