Dell PowerEdge M520 Dell Converged Enhanced Ethernet Administrator's Guide - Page 135
Configuring sFlow on specific interfaces, To customize sFlow on an interface
View all Dell PowerEdge M520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
Interface-specific administrative tasks for sFlow 12 To disable sFlow on a specific interface, perform the following steps in global configuration mode. 1. Enter interface mode for the port switch(config)#interface intengigabitethernet 0/12 2. Disable sFlow on the interface. switch(conf-if-te-0/12)f#no sflow enable 3. Confirm the sFlow configuration status on the specific interface. switch(conf-if)#exit switch(config)#exit switch#>show sflow interface intengigabitethernet 1/12 Configuring sFlow on specific interfaces You can enable sFlow and configure the polling interval and sample rate for a specific interface port on the switch. To customize sFlow on an interface, perform the following steps from Privileged EXEC mode. 1. Enter the interface command to specify the CEE interface type and slot/port number. switch(config)#interface extengigabitethernet 1/16 2. Enable sFlow for the interface. switch(conf-if-te-0/1)#sflow enable interface 3. Configure the sFlow polling interval. switch(conf-if-te-1/16)#sflow polling-interval 135 4. Set the sFlow sample-rate. switch(conf-if-te-1/16)#sflow sample-rate 8192 5. Confirm the sFlow configuration status on the specific interface. switch(conf-if-te-1/16)#exit switch(config)#exit switch#>show sflow interface extengigabitethernet 1/16 te 1/16 Configured sampling rate :8192 Actual sampling rate :8192 Counter polling interval :135 Samples rcvd from h/w :33 Dell Converged Enhanced Ethernet Administrator's Guide 117 53-1002116-01