Dell PowerEdge M520 Dell Converged Enhanced Ethernet Administrator's Guide - Page 55
Configuring an interface port as a trunk interface, Disabling a VLAN on a trunk interface
View all Dell PowerEdge M520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
VLAN configuration and management 5 Configuring an interface port as a trunk interface Each CEE interface port supports admission policies based on whether the frames are untagged or tagged. Trunk mode admits only VLAN-tagged frames. To configure the interface as a trunk interface, perform the following steps from Privileged EXEC mode. 1. Enter the configure terminal command to access global configuration mode. 2. Enter the interface command to specify the CEE interface type and slot/port number. switch(config)#interface intengigabitethernet 0/19 3. Enter the no shutdown command to enable the CEE interface. 4. Enter the switchport command to place the CEE interface into trunk mode. switch(conf-if-te-0/19)#switchport mode trunk 5. Specify whether all, one, or none of the VLAN interfaces are allowed to transmit and receive through the CEE interface. Enter the following command that is appropriate for your needs. • This example allows the VLAN numbered as 30 to transmit/receive through the CEE interface: switch(conf-if-te-0/19)#switchport trunk allowed vlan add 30 • To allow all VLANs to transmit/receive through the CEE interface: switch(conf-if-te-0/19)#switchport trunk allowed vlan all • This example allows all except VLAN 11 to transmit/receive through the CEE interface: switch(conf-if-te-0/19)#switchport trunk allowed vlan except 11 • To allow none of the VLANs to transmit/receive through the CEE interface: switch(conf-if-te-0/19)#switchport trunk allowed vlan none Disabling a VLAN on a trunk interface To disable a VLAN on a trunk interface, perform the following steps from Privileged EXEC mode. 1. Enter the configure terminal command to access global configuration mode. 2. Enter the interface command to specify the CEE interface type and slot/port number. switch(config)#interface intengigabitethernet 0/10 3. Enter the no shutdown command to enable the CEE interface. 4. Enter the switchport command to place the CEE interface into trunk mode. switch(conf-if-te-0/10)#switchport mode trunk none Configuring an interface port as a converged interface Each CEE interface port supports admission policies based on whether the frames are untagged or tagged. Converged mode admits both tagged and untagged frames. Any tagged frames coming with a VLAN tag equal to the configured native VLAN are dropped. Dell Converged Enhanced Ethernet Administrator's Guide 37 53-1002116-01