Dell PowerEdge R740xd2 EMC Installation and Service Manual - Page 107

Removing expansion card from the system board

Page 107 highlights

Table 18. Riser configurations: Butterfly riser + 3 x low profile - Processor 1 (continued) Card type Slot priority Maximum number of cards PERC 9/9.14G (Internal) Integrated Slot 1 Qlogic Qual Port LP card 3 1 40G LP card (Intel/mellanox) 3 NA PCIe SSD PCIe card (Intel) 3 1 Table 19. Riser configurations: Butterfly riser + 3 x low profile - Processor 1 and 2 Card type Slot priority Maximum number of cards LOM riser ; 2x1G BCM5720L (FXN) 1 1 LOM riser ; 2x10G BCM57416 (BASeT/SFP 1 1 +) (FXN) LOM riser: Broadcom 25G card, 930PP 1 1 RAID - PERC 9/9.14G/10 (External) 4, 3, 2, 5 4 Full Height (FH) Card Network, 2 1 (Broadcom/Intel/Mellanox 10G, 25G, 100G/Qlogic DP & QP 10GSEP) BOSS M.2 (SATA) (Dell) 2 1 PCIe SSD PCIe Card (Samsung) 4, 3, 5 3 Low Profile LP card 10G, 25G, 40G 4, 3, 5 4 (Broadcom/Intel/Mellanox/Qlogic Dual Port/Solarflare) BOSS M.2 (SATA) (Dell) 4, 3, 5 3 1G Card,Network (Broadcom/INTEL) 6, 5, 4, 3 4 RAID - PERC 9/9.14G (Internal) Integrated Slot 1 100G LP card (Mellanox) 4 1 Qlogic Qual Port LP card 4, 3 2 40G LP card(Intel/mellanox) 4,3 NA PCIe SSD PCIe card (Intel) 3 1 Removing expansion card from the system board Prerequisites 1. Follow the safety guidelines listed in Safety instructions. 2. Power off the system and all attached peripherals. 3. Disconnect the system from the electrical outlet, and disconnect the peripherals. 4. Open the drive bays, remove all drives, and then close the drive bays. 5. Remove the power supply units. 6. Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals. 7. Remove the air shroud. 8. If installed, remove the rear drive cage. 9. If installed, remove the expansion card risers. 10. If applicable, disconnect any cables connected to the expansion card. Installing and removing system components 107

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Table 18. Riser configurations: Butterfly riser + 3 x low profile - Processor 1
(continued)
Card type
Slot priority
Maximum number of cards
PERC 9/9.14G (Internal)
Integrated Slot
1
Qlogic Qual Port LP card
3
1
40G LP card (Intel/mellanox)
3
NA
PCIe SSD PCIe card (Intel)
3
1
Table 19. Riser configurations: Butterfly riser + 3 x low profile - Processor 1 and 2
Card type
Slot priority
Maximum number of cards
LOM riser ; 2x1G BCM5720L (FXN)
1
1
LOM riser ; 2x10G BCM57416 (BASeT/SFP
+) (FXN)
1
1
LOM riser: Broadcom 25G card, 930PP
1
1
RAID - PERC 9/9.14G/10 (External)
4, 3, 2, 5
4
Full Height (FH) Card Network,
(Broadcom/Intel/Mellanox 10G, 25G,
100G/Qlogic DP & QP 10GSEP)
2
1
BOSS M.2 (SATA) (Dell)
2
1
PCIe SSD PCIe Card (Samsung)
4, 3, 5
3
Low Profile LP card 10G, 25G, 40G
(Broadcom/Intel/Mellanox/Qlogic Dual
Port/Solarflare)
4, 3, 5
4
BOSS M.2 (SATA) (Dell)
4, 3, 5
3
1G Card,Network (Broadcom/INTEL)
6, 5, 4, 3
4
RAID - PERC 9/9.14G (Internal)
Integrated Slot
1
100G LP card (Mellanox)
4
1
Qlogic Qual Port LP card
4, 3
2
40G LP card(Intel/mellanox)
4,3
NA
PCIe SSD PCIe card (Intel)
3
1
Removing expansion card from the system board
Prerequisites
1.
Follow the safety guidelines listed in
Safety instructions
.
2.
Power off the system and all attached peripherals.
3.
Disconnect the system from the electrical outlet, and disconnect the peripherals.
4.
Open the drive bays
, remove
all drives
, and then
close the drive bays.
5.
Remove the
power supply units
.
6.
Remove the system from the rack and place it on an ESD work bench. For more information, see the
Rail Installation Guide
available at
www.dell.com/poweredgemanuals
.
7.
Remove the air shroud
.
8.
If installed,
remove the rear drive cage
.
9.
If installed,
remove the expansion card risers.
10.
If applicable, disconnect any cables connected to the expansion card.
Installing and removing system components
107