Dell PowerEdge R740xd2 EMC Installation and Service Manual - Page 79
Bay intrusion switch, Removing bay intrusion switch
![]() |
View all Dell PowerEdge R740xd2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Figure 54. Installing bay 2 backplane brackets Next steps 1. Place the system into the rack. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals. 2. Open the drive bays, install all drives, and then close the drive bays. 3. Install the power supply units. 4. If removed, install the front bezel. 5. Follow the procedure listed in After working inside your system. Bay intrusion switch Removing bay intrusion switch Prerequisites 1. Follow the safety guidelines listed in Safety instructions. 2. Follow the procedure listed in Before working inside your system. 3. If installed, remove the front bezel. 4. Open the drive bays. 5. Remove the drive bay 1 bracket. Steps 1. Disconnect the intrusion switch cable connected to the backplane of drive bay 1. 2. Using a Phillips #1 screwdriver, remove the screws securing the intrusion switch to the intrusion switch slot. 3. Disengage the intrusion switch from the intrusion switch slot and remove it from the system. Installing and removing system components 79