Dell PowerEdge R740xd2 EMC Installation and Service Manual - Page 123
M.2 SSD module, Removing the M.2 SSD module
View all Dell PowerEdge R740xd2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
Figure 105. Installing butterfly riser Next steps 1. If removed, install the rear drive cage. 2. Install the air shroud. 3. Install the system cover. 4. Place the system into the rack. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals. 5. Open the drive bays, install all drives, and then close the drive bays. 6. Install the power supply units. 7. Install any device drivers required for the card as described in the documentation for the card. 8. Follow the procedure listed in After working inside your system. M.2 SSD module Removing the M.2 SSD module Prerequisites 1. Follow the safety guidelines listed in Safety instructions. 2. Power off the system and all attached peripherals. 3. Disconnect the system from the electrical outlet, and disconnect the peripherals. 4. Open the drive bays, remove all drives, and then close the drive bays. 5. Remove the power supply units. 6. Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals. 7. Remove the system cover. 8. Remove the air shroud. 9. If installed, remove the rear drive cage. 10. Remove the BOSS card. Installing and removing system components 123