Dell PowerEdge T640 EMC PowerEdge T640 Installation and Service Manual - Page 103
Removing the optical drive cage or tape drive
View all Dell PowerEdge T640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
Figure 60. Installing the optical or tape drive blank Next steps 1. If removed, install the front bezel. 2. Follow the procedure listed in After working inside your system on page 66. Removing the optical drive cage or tape drive Prerequisites NOTE: The procedure to remove the optical drive cage is identical to removing a tape drive. 1. Follow the safety guidelines listed in Safety instructions on page 65. 2. Follow the procedure listed in Before working inside your system on page 66. 3. If installed, remove the front bezel. Steps 1. Disconnect the power and data cable from the back of the drive. NOTE: Observe the routing of the power and data cable inside the chassis as you remove them from the system board and the drive. You must route these cables properly when you replace them to prevent them from being pinched or crimped. 2. To remove the drive, push the release latch to release the drive. 3. Slide the drive out of the drive bay. 4. If you are not immediately replacing the tape drive, install the blank. NOTE: Blanks must be installed on empty optical drive or tape drive slots to maintain FCC certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system. Perform the same steps to install blanks. Installing and removing system components 103