Dell PowerStore 3000X EMC PowerStore Network Configuration Guide for PowerSwit
Dell PowerStore 3000X Manual
View all Dell PowerStore 3000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerStore 3000X manual content summary:
- Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 1
Dell EMC PowerStore Network Configuration Guide for Dell PowerSwitch Series Version 1.x September 2020 Rev. A02 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 2
use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 3
Contents Additional Resources...5 Chapter 1: PowerStore models and network hardware overview 6 Using this guide...6 PowerStore deployment models...7 PowerStore appliance nodes...7 Top-of-Rack (ToR) switches...8 Dell EMC PowerSwitch S4148F-ON...9 Dell EMC PowerSwitch S4148T-ON...9 Dell PowerSwitch - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 4
base enclosure to the ToR switches 58 Cable the ToR switches together...59 Cable the Top-of-Rack switches to the core uplinks 60 Chapter 9: PowerStore X model: Validate switch and network configuration 61 Validate configuration on the Top-of-Rack (ToR) switches 61 Network Validation Tool for - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 5
PowerStore Documentation page at https:// www.dell.com/powerstoredocs. ● Troubleshooting For information about products, software updates, licensing, and service, go to https://www.dell.com/support and locate the appropriate product support page. ● Technical support For technical support and service - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 6
an OOB management switch. Supporting documentation In addition to performing the configuration steps in this document, you should also read through the following guides prior to configuring your switches and networks: ● PowerStore Network Planning Guide 6 PowerStore models and network hardware - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 7
the system. NOTE: Hypervisor deployments are not supported on this model. Refer to Part 1: Configuring PowerStore T model Switches and Networks PowerStore X model appliance ● 1000X ● 3000X ● 5000X ● 7000X ● 9000X Supports only block (SAN-only) services with a hypervisor installed on the system - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 8
PowerStore Support Matrix for the list of supported switches. The Support Matrix is available from the Dell support site at: https://www.dell.com/support. Deploying with PowerSwitch Series PowerStore Installation Guide S5200F-ON Series Installation Guide OS10 Enterprise Edition User Guide - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 9
done through the serial console port. Serial Console Port Management Port Figure 4. S4000 series PSU-side Dell EMC PowerSwitch S4148T-ON You can configure PowerStore with two Dell EMC PowerSwitch S4148T-ON models. NOTE: This document uses the Dell EMC PowerSwitch S4148F-ON switch for examples in the - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 10
Dell PowerSwitch S5248F-ON You can configure PowerStore with dual Dell PowerSwitch S5248F-ON switch models. NOTE: In future chapters, this document uses through the serial console port. Management Port Figure 8. S5248 PSU-side Serial Console Port 10 PowerStore models and network hardware overview - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 11
diagrams demonstrate the logical network topology for a PowerStore T model deployment, and a PowerStore X model deployment. PowerStore T model logical topology Management Production ToR 1 ToR 2 Embedded module Embedded module PowerStore T base enclosure Management Subnets Remote Discovery - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 12
PowerStore X model logical topology Figure 10. PowerStore X model logical topology and network paths 12 PowerStore models and network hardware overview - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 13
T model: Configuring Networks Topics: • PowerStore T model: Before you begin • PowerStore T model: Configure the switches • PowerStore T model: Cabling the appliance to the switches • PowerStore T model: Validate switch and network configuration PowerStore T model: Configuring Networks 13 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 14
if you plan to deploy your PowerStore T model networks exactly as they are demonstrated in this guide. If you are configuring your environment a single component called cluster. Cluster Name PowerStoreTCluster Appliance Service Tags CNR42W2 The service tag appears on the black tag on the front - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 15
for a dedicated network that transfer virtual machines between appliances. 2 IPs for each PowerStore X model Appliance VLAN (Optional, Defaults to 0) Netmask/Prefix Length Gateway IP Addresses N/A N/A N/A N/A Infrastructure Services Record IP addresses for your DNS and NTP servers. It is - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 16
.10/24 Port Port 22 User Credentials / Community String admin/Password123! PowerStore T model Only Out-of-Band Management Switch Information You can provide read capability. It sends notifications to Dell EMC, enables remote support, and sends data to CloudIQ. Once your cluster is created - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 17
environment. To download a blank worksheet see Appendix C: PowerStore T model: Network Setup Preparation Worksheet (blank). See the PowerStore Network Planning Guide for details about reserving network resources. Table 5. PowerStore T model Network Setup Preparation Worksheet (example) Step Step - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 18
/24 Management IP address for switch 2 100.0.100.11/24 Default gateway 100.0.100.1 NTP server 100.0.100.200 10. Dell EMC supports deploying PowerStore T model with two Top-of-Rack (ToR) switches with a layer 2 interconnect link. Choose which type of layer 2 interconnect you will use: Highly - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 19
19. Determine if you will use a direct connection or a remote connection to discover your PowerStore. Once you have successfully discovered your PowerStore, you will be guided through the Initial Configuration Wizard to create your first PowerStore cluster. PowerStore T model: Before you begin 19 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 20
general settings on the Top-of-Rack (ToR) switches • Configure PowerStore T model production VLANs on the switch • Configure Virtual Link Trunking PowerSwitch S4100-ON Series Installation Guide located at: https://www.dell.com/support/home/us/en/04/product-support/product/networking-s4148f-on/docs - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 21
switch license see the OS10 Enterprise Edition User Guide for details. Steps 1. Establish a terminal Dell Digital Locker (www.dell.com/support/software/). OS10# show version Dell Digital Locker (www.dell.com/support/software/). OS10# show license PPID : CN00Y2VTCES0082O0038 Service Tag : D8MSG02 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 22
is already installed on the switch. 4. Repeat the steps for each switch. Configure the out-of-band management switch If you are deploying PowerStore T model perform the following steps to configure the out-of-band (OOB) management switch settings. Prerequisites Each management switch must have the - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 23
for the switch. ntp server 100.0.100.200 exit 9. Configure ethernet ports on the switch that will connect to the PowerStore T model management ports. interface ethernet 1/1/2 description "PowerStoreNodeA_MgmtPort" no shutdown switchport mode access switchport access vlan 100 exit interface ethernet - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 24
two ToR switches. Prerequisites In OS10EE, LLDP (Link Layer Discovery Protocol) is enabled globally on each interface by default. You can use LLDP for troubleshooting and validation. It is recommended that you enable all of the optional TLVs (type, length, value) in the LLDPU (Link Layer Discovery - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 25
address 100.0.100.10/24 exit configure terminal hostname Switch2 interface mgmt 1/1/1 no shutdown no ip address dhcp ip address 100.0.100.11/24 exit PowerStore T model: Configure the switches 25 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 26
100.0.100.1 ntp server 100.0.100.200 spanning-tree mode rstp spanning-tree rstp priority 45056 exit Configure PowerStore T model production VLANs on the switch About this task Configure the PowerStore T model production VLANs. Management Production ToR 1 ToR 2 Embedded module Embedded module - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 27
of connectivity. Refer to Cable the Top-of-Rack (ToR) Switches together for details. VLTi is required to configure Link Aggregation Control Protocol between the PowerStore nodes. Steps 1. Establish a terminal session to the first ToR switch (Switch1 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 28
to peers. NOTE: Steps to configure uplinks to the customer networks are not described in this guide. peer-routing 7. Set the priority of the switch. primary-priority 1 Valid priority values range -1/1/26 backup destination 100.0.100.10 peer-routing 28 PowerStore T model: Configure the switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 29
terminal interface port-channel 30 description Uplink no shutdown switchport mode trunk switchport access vlan 1 switchport trunk allowed vlan 200,300 vlt-port-channel 30 PowerStore T model: Configure the switches 29 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 30
Switch 1. no shutdown switchport mode trunk switchport access vlan 1 switchport trunk allowed vlan 200,300 5. Configure the ports that are connected to PowerStore T model nodes as spanning tree protocol (STP) edge ports. spanning-tree port type edge exit 6. Create VLT port-channel for Node B ports - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 31
ToR Switch 1. no shutdown switchport mode trunk switchport access vlan 1 switchport trunk allowed vlan 200,300 8. Configure the ports that are connected to PowerStore T model nodes as spanning tree protocol (STP) edge ports. spanning-tree port type edge exit 9. Move Node A facing port to the first - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 32
copy running-configuration startupconfiguration Switch 2 interface ethernet 1/1/54 channel-group 20 mode active flowcontrol receive off flowcontrol transmit off exit copy running-configuration startupconfiguration 32 PowerStore T model: Configure the switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 33
4 PowerStore T model: Cabling the appliance to the switches This chapter includes the following information. Topics: • Cable the out- switch. 2 Connect the management 1GbE port of the top node (B) to port 53 of the OOB management switch. PowerStore T model: Cabling the appliance to the switches 33 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 34
26 to the Management Uplink B. NOTE: Work with your network administrator to determine the uplink ports to which the OOB management switch will connect. 34 PowerStore T model: Cabling the appliance to the switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 35
54 of the bottom switch (1). 4 Connect Port 0 of the top node (B), to Port 54 of the top switch (2). Cable the ToR switches together PowerStore dual switch deployments with VLT, requires that the two Top of Rack (ToR) switches are cabled together. 1 2 Figure 15. Switch-to-switch connectivity - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 36
Use two cables that support connectivity between the high speed ports, for example 100Gbps Direct Attached Cables (DAC). Table uplinks. Core uplinks Uplink A Uplink B 1 3 4 2 Figure 16. ToR switch connections to the core uplinks 36 PowerStore T model: Cabling the appliance to the switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 37
top ToR switch to the core Uplink B. NOTE: Work with your network administrator to determine the uplink ports to which the ToR switches will connect. PowerStore T model: Cabling the appliance to the switches 37 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 38
the configuration on the out-of-band management switch • Validate configuration on the Top-of-Rack (ToR) switches • Network Validation Tool for PowerStore Validate the configuration on the out-of-band management switch After you have configured the out-of-band (OOB) management switch, and cabled - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 39
:36:9f:d4:fb:2e a0:36:9f:d4:fb:2e ethernet1/1/2 Dell EMC PowerStore 00:60:16:9d:02:5c cyc-coreos ethernet1/1/25 MGMT-01 ethernet1/1/31 68 26 MGMT-02 ethernet1/1/31 68:4f:64:58:9f:a5 ethernet1/1/53 Dell EMC PowerStore 00:60:16:9e:e6:2c cyc-coreos mgmt1/1/1 MGMT-01 ethernet1/1/41 68: - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 40
00:e0:ec:da:e4:f2 00:e0:ec:da:e4:f2 ethernet1/1/1 Dell EMC PowerStore 00:e0:ec:da:e4:e2 cyc-coreos ethernet1/1/25 Switch2 ethernet1/1/25 e4:f0:04 00:e0:ec:da:84:4f 00:e0:ec:da:84:4f ethernet1/1/54 Dell EMC PowerStore 00:e0:ec:da:84:3f cyc-coreos mgmt1/1/1 MGMT-01 ethernet1/1/42 68:4f:64 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 41
(https://psapps.emc.com/central/solutions). You must have an online support account to download the NVT. You can create an account from www.dell.com/support. Once you have downloaded the NVT, see the Network Validation Tool for PowerStore UserGuide.pdf, which is downloaded in the zip file with the - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 42
X model: Configuring Networks Topics: • PowerStore X model: Topology and connections • PowerStore X model: Configure switches • PowerStore X model: Cabling the appliance to the switches • PowerStore X model: Validate switch and network configuration 42 PowerStore X model: Configuring Networks - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 43
if you want to deploy your PowerStore X model networks exactly as they are demonstrated in this guide. ● Sample: Initial Configuration a single component called cluster. Cluster Name PowerStoreXCluster Appliance Service Tags CNR42W2 The service tag appears on the black tag on the front of - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 44
Table 14. PowerStore X model: completed example of an Initial Configuration Worksheet (continued) want to configure together as a cluster, and record their service tags. Networks Your cluster requires a dedicated set of IP addresses for each type of network. NOTE: VLAN information for management, - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 45
22 User Credentials / Community String admin/Password123! admin/Password123! PowerStore T model Only Out-of-Band Management Switch Information (Optional) You capability. It sends notifications to Dell EMC, enables remote support, and sends data to CloudIQ. Once your cluster is created - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 46
PowerStore X model Network Setup Preparation Worksheet. See the PowerStore Network Planning Guide for details for reserving network resources. Table 15. PowerStore 100.0.100.1 NTP server 100.0.100.200 8. Dell EMC supports deploying PowerStore X model with two Top-of-Rack (ToR) switches with - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 47
if you will use a direct connection or a remote connection to discover your PowerStore. Once you have successfully discovered your PowerStore, you will be guided through the Initial Configuration Wizard to create your first PowerStore cluster. PowerStore X model: Topology and connections 47 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 48
Configure general settings on the Top-of-Rack (ToR) switches • Configure PowerStore X model network VLANs on the switch • Configure Virtual Link Trunking interface S4100-ON Series Installation Guide located at: https://www.dell.com/support/home/us/en/04/product-support/product/networking-s4148f-on - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 49
the switch license see the OS10 Enterprise Edition User Guide for details. Steps 1. Establish a terminal connection Dell Digital Locker (www.dell.com/support/software/). OS10# show version Dell EMC r0 PPID : CN00Y2VTCES0082O0038 Service Tag : D8MSG02 License PowerStore X model: Configure switches 49 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 50
Layer Discovery Protocol) is enabled globally on each interface by default. You can use LLDP for troubleshooting and validation. It is recommended that you enable all of the optional TLVs (type, length, (RSTP) on the switch. spanning-tree mode rstp 50 PowerStore X model: Configure switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 51
100.0.100.11/24 exit management route 0.0.0.0/0 100.0.100.1 ntp server 100.0.1000.200 spanning-tree mode rstp spanning-tree rstp priority [45056] exit Configure PowerStore X model network VLANs on the switch About this task Configure the - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 52
X base enclosure Management VLANS or Subnets Remote Discovery Management Production VLANS or Subnets Storage vMotion Internal Figure 17. PowerStore X model VLANs Steps 1. Establish a terminal connection to the switch to the first ToR switch (Switch1) 2. Enter global configuration mode. configure - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 53
L2 mode on the 100 GbE ports that will be used for VLTi on Switch1. interface range ethernet 1/1/25-1/1/26 description vlti no switchport exit PowerStore X model: Configure switches 53 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 54
. NOTE: Steps to configure uplinks to the customer networks are not described in this guide. peer-routing 7. Set the priority of the switch. primary-priority 1 Valid priority to know that VLTi configurations for PowerStore X model require that port channels are configured for the uplink ports to - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 55
X model node connectivity You configure the port interfaces between the PowerStore X model nodes and the ToR switches. Steps 1. Establish a terminal connection to the switch to the first ToR switch (Switch1) 2. Enter global configuration mode. configure terminal 3. - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 56
channel-group 30 mode active no switchport flowcontrol receive off flowcontrol transmit off 5. Commit the configuration to the nvram. copy running-configuration startup-configuration 56 PowerStore X model: Configure switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 57
interface ethernet 1/1/30 description Uplink_Ports no shutdown channel-group 30 mode active no switchport flowcontrol receive off flowcontrol transmit off copy running-configuration startup-configuration PowerStore X model: Configure switches 57 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 58
8 PowerStore X model: Cabling the appliance to the switches This chapter contains the following information. Topics: • Cable the base 54 of the bottom switch (1). 4 Connect Port 0 of the top node (B), to Port 54 of the top switch (2). 58 PowerStore X model: Cabling the appliance to the switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 59
Cable the ToR switches together PowerStore dual switch deployments with VLT, requires that the two Top of Rack (ToR) switches are cabled together. 1 2 Figure 19. Switch-to-switch connectivity Use two cables that support connectivity between the high speed ports, for example 100Gbps Direct - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 60
ToR switch to the core Uplink B. NOTE: Work with your network administrator to determine the uplink ports to which the ToR switches will connect. 60 PowerStore X model: Cabling the appliance to the switches - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 61
This chapter contains the following information. Topics: • Validate configuration on the Top-of-Rack (ToR) switches • Network Validation Tool for PowerStore Validate configuration on the Top-of-Rack (ToR) switches Once you have configured and cabled your ToR switches, validate the configuration - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 62
backup link show vlt backup-link VLT Backup Link Destination Peer Heartbeat status Heartbeat interval Heartbeat timeout : 100.0.100.11 : Up : 30 : 90 62 PowerStore X model: Validate switch and network configuration - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 63
(https://psapps.emc.com/central/solutions). You must have an online support account to download the NVT. You can create an account from www.dell.com/support. Once you have downloaded the NVT, see the Network Validation Tool for PowerStore UserGuide.pdf, which is downloaded in the zip file with the - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 64
/central/solutions. ● Ensure that your workstation's Ethernet adapter is configured as follows: ○ Connected directly to the PowerStore service port on node A. ○ Configured with a static IP address on the service LAN network (128.221.1.0/24) with no gateway address defined (128.221.1.249; 255.255.255 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 65
ensure that you exit and restart the Discovery Utility after temporarily disabling the firewall or antivirus services. Steps 1. From your workstation or virtual machine, launch the PowerStore Discovery Utility. 2. Select the unconfigured base enclosure for which you want to create a cluster. 3. Log - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 66
● Default password: Password123# 66 Discovering PowerStore Appliances - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 67
[yes/no]:n Proceed to reboot the system? [confirm yes/no]:y PowerStore T model: Running configuration of PowerSwitch Series Use the following command to :19:20 2020 ! snmp-server contact http://www.dell.com/support hostname oobMgmtSwitch interface breakout 1/1/25 map 100g-1x interface breakout 1/1/ - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 68
interface breakout 1/1/29 map 100g-1x interface breakout 1/1/30 map 100g-1x username admin password $6$rounds=656000$.zmPnShW0cq6sTTl $8VG.h5byJqnohgTkw3Vhn5yAU7SKQtpOLOaaYmcxEXiDLWw4jOma/Di/1dEJQlYStbN.fbwrsTltlX8hdwQlG. role sysadmin ntp server 100.0.100.200 iscsi enable iscsi target port 860 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 69
! interface ethernet1/1/8 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/9 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/10 shutdown switchport access vlan 1 flowcontrol receive - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 70
interface ethernet1/1/20 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/21 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/22 shutdown switchport access vlan 1 flowcontrol receive - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 71
flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/34 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/35 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/36 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 72
off flowcontrol transmit off ! interface mgmt1/1/1 no shutdown no ip address dhcp ip address 100.0.100.50/24 ipv6 address autoconfig ! management route 0.0.0.0/0 100.0.100.1 ! support-assist 72 Other Dell EMC PowerSwitch configuration operations - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 73
switches Switch1 Switch 2 ! Version 10.4.1.4 ! Last configuration change at Mar 19 04:24:55 2020 ! snmp-server contact http://www.dell.com/ support hostname Switch1 interface breakout 1/1/25 map 100g-1x interface breakout 1/1/26 map 100g-1x interface breakout 1/1/29 map 100g-1x interface breakout - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 74
Table 23. Running configuration for ToR switches Switch1 switchport access vlan 1 switchport trunk allowed vlan 200,300 vlt-port-channel 30 ! interface ethernet1/1/1 description Node-A-Port-0 no shutdown channel-group 10 mode active no switchport flowcontrol receive off flowcontrol transmit off ! - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 75
Table 23. Running configuration for ToR switches Switch1 switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/12 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/13 shutdown switchport access vlan - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 76
Table 23. Running configuration for ToR switches Switch1 flowcontrol transmit off ! interface ethernet1/1/23 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/24 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 77
Table 23. Running configuration for ToR switches Switch1 interface ethernet1/1/35 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/36 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/ - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 78
mgmt1/1/1 no shutdown no ip address dhcp ip address 100.0.100.10/24 ipv6 address autoconfig ! management route 0.0.0.0/0 100.0.100.1 ! support-assist ! vlt-domain 1 backup destination 100.0.100.11 discovery-interface ethernet1/1/25-1/1/26 peer-routing Switch 2 switchport access vlan 1 flowcontrol - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 79
Switch 2 primary-priority 1 vlt-mac 00:00:00:00:00:01 PowerStore X model: Running configuration of PowerSwitch Series Use the following command to generate 24:55 2020 ! snmp-server contact http://www.dell.com/ support hostname Switch1 interface breakout 1/1/25 map 100g-1x interface breakout 1/1/ - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 80
Table 24. Example of running-configuration on ToR switches Switch1 Switch 2 no shutdown switchport mode trunk switchport access vlan 1 switchport trunk allowed vlan 100,200,400 vlt-port-channel 30 ! interface ethernet1/1/1 description Node-A-Port-0 no shutdown switchport mode trunk switchport - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 81
Table 24. Example of running-configuration on ToR switches Switch1 Switch 2 flowcontrol transmit off ! interface ethernet1/1/11 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/12 shutdown switchport access vlan 1 flowcontrol receive off - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 82
Table 24. Example of running-configuration on ToR switches Switch1 Switch 2 interface ethernet1/1/22 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/23 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 83
Table 24. Example of running-configuration on ToR switches Switch1 Switch 2 switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/35 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/36 shutdown - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 84
no shutdown no ip address dhcp ip address 100.0.100.10/24 ipv6 address autoconfig ! management route 0.0.0.0/0 100.0.100.1 ! support-assist flowcontrol transmit off ! interface ethernet1/1/46 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 85
-domain 1 backup destination 100.0.100.11 discovery-interface ethernet1/1/25-1/1/26 peer-routing primary-priority 1 vlt-mac 00:00:00:00:00:01 support-assist ! vlt-domain 1 backup destination 100.0.100.10 discovery-interface ethernet1/1/25-1/1/26 peer-routing primary-priority 1 vlt-mac 00:00:00:00 - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 86
available with the product and feature documentation on the PowerStore Documentation page at https://www.dell.com/powerstoredocs. Table each type of network. Cluster IP Address Management Network Connects the cluster to services such as DNS and NTP. The IP addresses in the management network are - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 87
used for a dedicated network that transfer virtual machines between appliances. 2 IPs for each PowerStore X model Appliance VLAN (Optional, Defaults to 0) Netmask/Prefix Length Gateway IP Addresses Infrastructure Services Record IP addresses for your DNS and NTP servers. It is recommended that - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 88
(Optional) You can provide read-only credentials for the switches. PowerStore X model Only Protocol (SSH / SNMP) IP Address Port User and system monitoring capability. It sends notifications to Dell EMC, enables remote support, and sends data to CloudIQ. Once your cluster is created successfully, - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 89
and networks. This table assumes you have read through and are familiar with the network requirements described in the PowerStore Network Planning Guide. Table 26. PowerStore T model Network Setup Preparation Worksheet (blank) Step Step details Notes 1. Print this table to record the reserved - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 90
of-band management switch Management IP address for switch 1 Management IP address for switch 2 Default gateway NTP server 10. Dell EMC supports deploying PowerStore T model with two Top-of-Rack (ToR) switches with a layer 2 interconnect link. Choose which type of layer 2 interconnect you will - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 91
a direct connection or a remote connection to discover your PowerStore. Once you have successfully discovered your PowerStore, you will be guided through the Initial Configuration Wizard to create your first PowerStore cluster. PowerStore X model Network Setup Preparation Worksheet Work with your - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 92
configure the switch below: Management IP address for switch 1 Management IP address for switch 2 Default gateway NTP server 8. Dell EMC supports deploying PowerStore X model with two Top-of-Rack (ToR) switches with a layer 2 interconnect link. Choose which type of layer 2 interconnect you - Dell PowerStore 3000X | EMC PowerStore Network Configuration Guide for PowerSwit - Page 93
15. Determine if you will use a direct connection or a remote connection to discover your PowerStore. Once you have successfully discovered your PowerStore, you will be guided through the Initial Configuration Wizard to create your first PowerStore cluster. Network Setup Preparation Worksheets 93
Dell EMC PowerStore
Network Configuration Guide for Dell PowerSwitch
Series
Version 1.x
September 2020
Rev. A02