Installing Options, Make sure both slide switches are set to the same position or
View all Epson EPL-N2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
7. Now set the jumper and slide switch settings on the LocalTalk/Serial module for the type of interface you'll be using: RS-232C serial, current loop serial, or LocalTalk (default). slide switch jumper switch c Caution: Make sure both slide switches are set to the same position or the printer will not operate correctly. 8. Position the module as shown below; then align its connector with connector CN4 on the controller board. Secure the module with the two screws that came with it. 4-8 Installing Options
4-8
Installing Options
7.
Now set the jumper and slide switch settings on the
LocalTalk/Serial module for the type of interface you’ll be
using: RS-232C serial, current loop serial, or LocalTalk
(default)
.
c
Caution:
Make sure both slide switches are set to the same position or the
printer will not operate correctly.
8.
Position the module as shown below; then align its
connector with connector CN4 on the controller board.
Secure the module with the two screws that came with it.
jumper switch