Fluke TI450 SF6 User Manual - Page 36

Spot Markers, Center Box, Measurement, Markers, All Off, One Marker, Three Markers, Cancel

Page 36 highlights

Ti200, Ti300, Ti400,Ti450 Users Manual Spot Markers Up to three adjustable, fixed-temperature spot markers are available on the display. You can use these markers to highlight a region before you save the image. The marker selection is set as All Off, One Marker, Two Markers, or Three Markers. To set a Marker: 1. Go to Measurement > Markers. 2. Push the / to highlight the function between All Off, One Marker, Two Markers, and Three Markers. 3. Push  to set the marker option and go to the "Move Marker" display. You will see the Move Marker icon and the labels on the function buttons change to Done, Next, and Cancel. To change the Marker position on the display: 1. Push to move the Marker location on the image. 2. Push  to highlight the next marker. Do Step 1 again. 3. Do Step 2 for a third marker. 4. Push  when done. Center Box The Center Box feature is an adjustable temperature measurement zone (box) that you can center on the infrared image. This zone (box) expands and contracts to different levels within the infrared image. The zone lets the user see an approximate maximum (MAX), average (AVG), and minimum (MIN) temperature measurement in that area. When in Auto Level and Span mode, the Imager automatically sets the level and span according to the infrared scene within the parameters of the Center Box. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Ti200, Ti300, Ti400,Ti450
Users Manual
32
Spot Markers
Up to three adjustable, fixed-temperature spot markers are available on the
display. You can use these markers to highlight a region before you save the
image. The marker selection is set as All Off, One Marker, Two Markers, or
Three Markers.
To set a Marker:
1.
Go to
Measurement
>
Markers
.
2.
Push the
/
to highlight the function between
All Off
,
One Marker
,
Two Markers
, and
Three Markers
.
3.
Push
to set the marker option and go to the “Move Marker” display.
You will see the Move Marker icon and the labels on the function buttons
change to
Done
,
Next
, and
Cancel
.
To change the Marker position on the display:
1.
Push
to move the Marker location on the image.
2.
Push
to highlight the next marker. Do Step 1 again.
3.
Do Step 2 for a third marker.
4.
Push
when done.
Center Box
The Center Box feature is an adjustable temperature measurement zone (box)
that you can center on the infrared image. This zone (box) expands and
contracts to different levels within the infrared image. The zone lets the user
see an approximate maximum (MAX), average (AVG), and minimum (MIN)
temperature measurement in that area. When in Auto Level and Span mode,
the Imager automatically sets the level and span according to the infrared
scene within the parameters of the Center Box.