Fluke TI450 SF6 User Manual - Page 38
Palette, Table 5. Palettes, Standard Palettes, Ultra Contrast, Image, Standard
View all Fluke TI450 SF6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Ti200, Ti300, Ti400,Ti450 Users Manual Palette The Palette menu lets you change the false-color presentation of the infrared images on display or captured. Some palettes are more suitable for specific applications and can be set as required. Two different palette presentation modes are available, see Table 5. The Standard Palettes offer an equal, linear presentation of colors that allow for best presentation of detail. The Ultra Contrast Palettes offer a weighted presentation of colors. These palettes work best in situations with high thermal contrast for extra color contrast between the high temperatures and low temperatures. Table 5. Palettes Standard Palettes Grayscale Grayscale Inverted Blue-Red High Contrast Hot Metal Ironbow Amber Amber Inverted Ultra Contrast Palettes Grayscale Ultra Grayscale Inverted Ultra Blue-Red Ultra High Contrast Ultra Hot Metal Ultra Ironbow Ultra Amber Ultra Amber Inverted Ultra To switch between palettes: 1. Go to Image > Palette > Standard or Ultra Contrast. 2. Push / to highlight a palette. 3. Push to set the new palette. 34