Fluke TI450 SF6 User Manual - Page 69

Image Presentation, Image Capture and Data Storage, Amber Ultra, Hot Metal Ultra, Ironbow

Page 69 highlights

Thermal Imagers Detailed Specifications Image Presentation Standard Palettes Blue-Red, Grayscale, Inverted Grayscale, High Contrast, Amber, Inverted Amber, Hot Metal, Ironbow Ultra Contrast™ Palettes Blue-Red Ultra, Grayscale Ultra, Inverted Grayscale Ultra, High Contrast Ultra, Amber Ultra, Inverted Amber Ultra, Hot Metal Ultra, Ironbow Ultra Level and Span Smooth Auto-Scaling and Manual scaling of level and span Fast auto toggle between manual and auto modes Fast auto rescale in manual mode Minimum Span (in manual mode 2.0 °C (3.6 °F) Minimum Span (in auto mode 3.0 °C (5.4 °F) Image Capture and Data Storage Image Capture, Review, Save Mechanism ........ One-handed image capture, review, and save capability Storage Medium Internal On-board Flash Memory 4 GB Micro SD Memory Card Includes ≥4 GB memory card to store at least 2000 fully radiometric (.is2) IR and linked visual images each with 60 sec voice annotations or 5000 basic (.bmp, .jpg) files USB Storage Device USB port available (USB storage device not included) Note The addition of IR-PhotoNotes or other saved items can vary the total number of images that can be stored in internal memory or on the SD memory card. File Formats Non-Radiometric (.bmp, .jpg) or FullyRadiometric (.is2) No analysis software required for NonRadiometric (.bmp, .jpg) files Export File Formats with SmartView Software Bitmap (.bmp), GIF, JPEG, PNG, TIFF Memory Review Thumbnail and full screen review 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Thermal Imagers
Detailed Specifications
65
Image Presentation
Standard Palettes
...............................................
Blue-Red, Grayscale, Inverted
Grayscale, High Contrast, Amber,
Inverted Amber, Hot Metal, Ironbow
Ultra Contrast™ Palettes
....................................
Blue-Red Ultra, Grayscale Ultra,
Inverted Grayscale Ultra, High
Contrast Ultra, Amber Ultra, Inverted
Amber Ultra, Hot Metal Ultra, Ironbow
Ultra
Level and Span
Smooth Auto-Scaling and Manual scaling of level and span
Fast auto toggle between manual and auto modes
Fast auto rescale in manual mode
Minimum Span (in manual mode)
...................
2.0
°
C (3.6
°
F)
Minimum Span (in auto mode)
.......................
3.0
°
C (5.4
°
F)
Image Capture and Data Storage
Image Capture, Review, Save Mechanism
........
One-handed image capture, review,
and save capability
Storage Medium
Internal On-board Flash Memory
....................
4 GB
Micro SD Memory Card
..................................
Includes
4 GB memory card to store
at least 2000 fully radiometric (.is2) IR
and linked visual images each with
60 sec voice annotations or
5000 basic (.bmp, .jpg) files
USB Storage Device
.......................................
USB port available (USB storage
device not included)
Note
The addition of IR-PhotoNotes or other saved items can vary the total number
of images that can be stored in internal memory or on the SD memory card.
File Formats
........................................................
Non-Radiometric (.bmp, .jpg) or Fully-
Radiometric (.is2)
No analysis software required for Non-
Radiometric (.bmp, .jpg) files
Export File Formats with
SmartView Software
...........................................
Bitmap (.bmp), GIF, JPEG, PNG, TIFF
Memory Review
..................................................
Thumbnail and full screen review