Fujitsu MAN3367FC Manual/User Guide - Page 120

Connector Signal Allocation

Page 120 highlights

Connector Signal Allocation B.1 Interface (FC-SCA) Connector Signal Allocation Table B.1 FC-SCA connector: CN1 Pin No. 01 02 03 04 05 06 07 08 09 10 11 12* 13* 14* 15* 16 17 18 19 20 Signal -EN bypass port A +12V +12V +12V -Parallel ESI -Drive present Active LED out -Spindle sync Start_1/Mated Start_2/Mated -EN bypass port B SEL-6 -DSK_WR SEL-5 -DSK_RD SEL-4 -ENCL_ACK SEL-3 D(3) Fault LED out DEV_CTRL_CODE2 DEV_CTRL_CODE1 +5V +5V Signal +12V charge GND GND +PortA_in -PortA_in GND +PortB_in -PortB_in GND +PortA_out -PortA_out GND +PortB-out -PortB-out GND SEL-2 D(2) SEL-1 D(1) SEL-0 D(0) DEV_CTRL_CODE0 +5V charge Note: *1) Signal names in the right column of the table are those in parallel ESI operation. Pin No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36* 37* 38* 39 40 B-2 C141-E133-02EN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Connector Signal Allocation
B-2
C141-E133-02EN
B.1
Interface (FC-SCA) Connector Signal Allocation
Table B.1
FC-SCA connector:
CN1
Pin No.
Signal
Signal
Pin No.
01
–EN bypass port A
+12V charge
21
02
+12V
GND
22
03
+12V
GND
23
04
+12V
+PortA_in
24
05
–Parallel ESI
–PortA_in
25
06
–Drive present
GND
26
07
Active LED out
+PortB_in
27
08
–Spindle sync
–PortB_in
28
09
Start_1/Mated
GND
29
10
Start_2/Mated
+PortA_out
30
11
–EN bypass port B
–PortA_out
31
12*
SEL-6
–DSK_WR
GND
32
13*
SEL-5
–DSK_RD
+PortB-out
33
14*
SEL-4
–ENCL_ACK
–PortB-out
34
15*
SEL-3
D(3)
GND
35
16
Fault LED out
SEL-2
D(2)
36*
17
DEV_CTRL_CODE2
SEL-1
D(1)
37*
18
DEV_CTRL_CODE1
SEL-0
D(0)
38*
19
+5V
DEV_CTRL_CODE0
39
20
+5V
+5V charge
40
Note:
*1) Signal names in the right column of the table are those in parallel ESI operation.