Specifications 2.1.3 Environmental specifications Table 2.2 lists environmental and power requirements. Table 2.2 Environmental/power requirements Item Operating Non-operating Temperature Transport (within a week) (*1) DE surface temperature at operating Gradient Operating Relative humidity Non operating Transport (within a week) Maximum wet bulb temperature Operating (*3) Vibration (*2) Non-operating (*4) Transport (packaged) Operating Shock (*2) Non-operating Transport (packaged) Altitute Operating (above sea level) Non-operating +12 VDC Ready ±5% (Average) Peak within 100 µs at spin-up Power requirements Input power (*5) +5 VDC ±5% Random W/R (about 80 IOPS) Ready (Average) Random W/R (about 80 IOPS) Ripple (*6) Specification MAN3735 series MAN3367 series 5 to 50°C -10 to 60°C -40 to 60°C 5 to 55°C 15°C/h or less 20 to 80%RH 20 to 80%RH 5 to 90%RH 29°C (no condensation) 0.3 mm (5 to 20Hz)/9.8 m/s2 (1G) (20 to 300 Hz) or less 3.1 mm (5 to 20Hz)/49m/s2 (5G) (20 to 300Hz) or less 3.1 mm (5 to 20Hz)/49m/s2 (5G) (20 to 300Hz) or less 637.4m/s2 (65G) (2 ms) 1961.3m/s2 (200G) (2 ms) 1961.3m/s2 (200G) (2 ms) -60 m to 3,000 m -60 m to 12,000 m 0.6 A 0.45 A 3.0 A 0.9 A 0.7 A 0.9 A 1.2 A +5 V/+12 V 250 mVp-p 2-4 C141-E133-02EN