Fujitsu MAN3367FC Manual/User Guide - Page 69
Setting, Loop ID setting, Mode settings, Table 5.1, Motor start mode, IMPORTANT
View all Fujitsu MAN3367FC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
5.2 Setting 5.2 Setting 5.2.1 Loop ID setting When setting the fibre channel loop ID, use SEL0 to SEL6 of interface connector CN1. IN bit weighting, SEL6 corresponds to the MSB, SEL0 to the LSB, and 126 types of X'00' to X'7D' can be specified as loop IDs. 5.2.2 Mode settings (1) Motor start mode The method for start control of the IDD spindle motor can be set in accordance with Table 5.1. Table 5.1 Motor start mode Setting Signal name Start_2/Mated Start_1/Mated Connector pin CN1-10 CN1-09 Open Open Open GND GND Open GND GND Start mode The drive is not connected to the system. The drive does not start the spindle motor. The drive is connected to the system. After recognizing the connection, the drive starts the spindle motor upon receipt of a START/STOP UNIT command. The drive is connected to the system. After recognizing the connection, the drive starts the spindle motor after a prescribed delay time has elapsed. The drive is connected to the system. The driver starts the spindle motor immediately after recognizing the connection. IMPORTANT Set the loop ID so that there are no duplicates between devices on the same loop. C141-E133-02EN 5-3