HP DL320 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 25

Hard Drive Overview, Guidelines for Installing ATA Hard Drives

Page 25 highlights

Removal and Replacement Procedures Hard Drive Overview The server contains two drive bays for either ATA or SCSI hard drives. There are two ATA channels and the server ships standard with two 1-inch drive trays and is preconfigured for two 1-inch ATA hard drives. The following sections provide general guidelines and installation procedures for installing or upgrading hard drives. Guidelines for Installing ATA Hard Drives When installing ATA hard drives in the server, observe the following general guidelines: • Populate hard drive bays starting with the lowest ATA device number. Device 0 serves as the primary boot drive. • Set the jumpers on both ATA drives to Cable-Select mode. • Do not add more than two ATA drives per channel. IMPORTANT: ATA hard drives must be configured to the Cable-Select mode. NOTE: ATA drives are set to Cable-Select mode by default. NOTE: Refer to the documentation shipped with the hard drive to determine how to set the jumpers on the ATA hard drives to Cable-Select mode, if they are not already set in Cable-Select mode. 2-14 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

Removal and Replacement Procedures
Hard Drive Overview
The server contains two drive bays for either ATA or SCSI hard drives. There are two ATA
channels and the server ships standard with two 1-inch drive trays and is preconfigured for
two 1-inch ATA hard drives. The following sections provide general guidelines and
installation procedures for installing or upgrading hard drives.
Guidelines for Installing ATA Hard Drives
When installing ATA hard drives in the server, observe the following general guidelines:
Populate hard drive bays starting with the lowest ATA device number. Device 0 serves as
the primary boot drive.
Set the jumpers on both ATA drives to Cable-Select mode.
Do not add more than two ATA drives per channel.
IMPORTANT:
ATA hard drives must be configured to the Cable-Select mode.
NOTE:
ATA drives are set to Cable-Select mode by default.
NOTE:
Refer to the documentation shipped with the hard drive to determine how to set the jumpers on
the ATA hard drives to Cable-Select mode, if they are not already set in Cable-Select mode.