HP DL320 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 69
System Unit, Table 5-1, System Unit Specifications
UPC - 829160513218
View all HP DL320 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
Specifications System Unit Table 5-1: System Unit Specifications Item Description Height 4.19 cm (1.65 in) Depth 65.45 cm (25.75 in) Width 42.55 cm (16.75 in) Weight (maximum) 11.81 kg (26 lb) Weight (no drives installed) 9.54 kg (21 lb) U.S. and international input voltage requirements Rated input voltage 100 VAC to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 2.8 A (110 V) to 1.4 A (220 V) Rated input power 307 W Maximum peak power 200 W (for max. duration of two minutes) BTUs per hour Temperature range1 1048 Operating 10°C to 35°C (50°F to 95°F) Shipping Relative humidity (noncondensing)2 -40°C to 70°C (-40°F to 158°F) Operating 10% to 90% Non-operating 5% to 95% Maximum wet-bulb temperature 28°C (82.4°F) 1Operating temperature has an altitude derating of 1°C per 308.4 M (1.8°F per 1000 ft). No direct sunlight. 2Storage maximum humidity of 95 percent based on maximum temperature of 45°C (113°F). Altitude minimum for storage is 70 kpa. 5-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:55 PM