Page 29 highlights

6 Removing and storing ElectroInk Silver and BID If you are not using the HP Indigo ElectroInk Silver for a few days, do the following: 1. Activate the ink pump for two minutes. 2. Drain the ink into a clean container. The ElectroInk Silver solution can be kept in a closed container up to one month, provided that it is shaken once a week. 3. On the closed container, write the conductivity and density values. When the ElectroInk Silver solution is reused, calibrate the ink with these values. 4. Store the container. It is recommended to store it in an environment that is the same as the press environment. 5. Clean the ink station and BID with the on-press fast ink replacement (OFIR). If you do not have an OFIR kit, you should fill the tank with clean imaging oil and circulate the pump until the imaging oil is clean. Several imaging oil replacements are needed. 6. Mark the BID for later use, as follows: a. Go to Main Menu > Ink and BID > BID > BID Care. b. Select the primer BID and touch Next. c. In theBID Care screen, touch Later use. Removing and storing ElectroInk Silver and BID 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Removing and storing ElectroInk Silver and
BID
6
If you are not using the HP Indigo ElectroInk Silver for a few days, do the following:
1.
Activate the ink pump for two minutes.
2.
Drain the ink into a clean container. The ElectroInk Silver solution can be kept in a closed container
up to one month, provided that it is shaken once a week.
3.
On the closed container, write the conductivity and density values. When the ElectroInk Silver
solution is reused, calibrate the ink with these values.
4.
Store the container. It is recommended to store it in an environment that is the same as the press
environment.
5.
Clean the ink station and BID with the on-press fast ink replacement (OFIR). If you do not have an
OFIR kit, you should fill the tank with clean imaging oil and circulate the pump until the imaging oil is
clean. Several imaging oil replacements are needed.
6.
Mark the BID for later use, as follows:
a.
Go to
Main Menu > Ink and BID > BID > BID Care
.
b.
Select the primer BID and touch
Next
.
c.
In the
BID Care
screen, touch
Later use
.
Removing and storing ElectroInk Silver and BID