HP Indigo WS6600 Working with Indigo ElectroInk SilverHow-to Guide - Page 33

Accumulation of background at the leading edge, When this issue is noticeable do the following

Page 33 highlights

Table 7-2 UI notifications (continued) # Scenario Example Old text UI notification Actual printing logic 3 Disengage limit was reached (e.g. overlap disengage calculation is above 990). Calculation: Image placement + manual correction + RL > 990 Image placement 0; Job RL 990; Disengage 20. OR Repeat length is above maximum. Maximum allowed values are used. It is recommended to perform BID Engage. Current trailing edge settings are invalid. Overlap prevention cannot be performed. Image placement 100; Job RL 900; Disengage 10. Overlap is disabled. 4 Disengage limit was reached by automatic overlap. Job RL 900; Image placement 100 Calculation: Image placement + RL > 990 -Did not exist- Current trailing edge settings are above the maximum value. Maximum values will be used. Overlap is trimmed to the maximum allowed, keeping the RL as it is. In the given example: Engage 90, Disengage 990. Accumulation of background at the leading edge Follow these steps for accumulation of background at the leading edge. In some cases (high coverage jobs, noticeable with rich black design) a narrow band may appear at the trailing edge area, across the frame. See example below: Frame #n Frame #n +1 Band X20 magnification of band area TE When this issue is noticeable do the following: 1. Verify LE BID engage is calibrated properly. Re-calibrate per need. 2. Enable the "overlap prevention" feature. (See Automatic overlap adjustments on page 17). 3. Use the overlap manual correction screen under Job Properties and re-adjust the BID engage by forwarding it by +10 mm. (See Manual overlap adjustments on page 18). 4. Re-print a proof and adjust per need: Accumulation of background at the leading edge 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Table 7-2
UI notifications
(continued)
#
Scenario
Example
Old text
UI notification
Actual printing logic
3
Disengage limit was
reached (e.g. overlap
disengage calculation
is above 990).
Calculation: Image
placement + manual
correction + RL > 990
Image
placement 0; Job
RL 990;
Disengage 20.
OR
Image
placement 100;
Job RL 900;
Disengage 10.
Repeat length is above
maximum. Maximum
allowed values are used.
It is recommended to
perform BID Engage.
Current trailing edge
settings are invalid.
Overlap prevention
cannot be performed.
Overlap is
disabled
.
4
Disengage limit was
reached by automatic
overlap.
Calculation: Image
placement + RL > 990
Job RL 900;
Image
placement 100
—Did not exist—
Current trailing edge
settings are above
the maximum value.
Maximum values will be
used.
Overlap is
trimmed
to
the maximum allowed,
keeping the RL as it is.
In the given example:
Engage 90, Disengage
990.
Accumulation of background at the leading edge
Follow these steps for accumulation of background at the leading edge.
In some cases (high coverage jobs, noticeable with rich black design) a narrow band may appear at the
trailing edge area, across the frame. See example below:
Frame #n
Frame #n +1
Band
TE
X20 magnification of band area
When this issue is noticeable do the following:
1.
Verify LE BID engage is calibrated properly. Re-calibrate per need.
2.
Enable the “overlap prevention” feature. (See
Automatic overlap adjustments
on page
17
).
3.
Use the overlap manual correction screen under Job Properties and re-adjust the BID engage by
forwarding it by +10 mm. (See
Manual overlap adjustments
on page
18
).
4.
Re-print a proof and adjust per need:
Accumulation of background at the leading edge
29