HP LH4r HP Netserver LP 2000r User Guide - Page 86

Removing a Power Supply Module

Page 86 highlights

Chapter 9 Connecting the Monitor, Keyboard, Mouse, and UPS 3. Slide the module into the power bay and press the release lever in until it clicks into place. See Figure 9-5. Figure 9-5. Installing a Power Supply Module 4. Plug in the power cord for the power supply module. See Figure 9-2. Removing a Power Supply Module If only one power supply module is used, it must be installed in power supply bay 2, and a power supply filler panel must be inserted in the empty bay 1. CAUTION Operating the HP Netserver without a power supply filler panel in an empty power supply bay could cause excessive EMI or thermal damage to the Netserver. 1. Pinch the release lever on the power supply module and pull on the lever to slide module out of the power bay. See Figure 9-6. 80

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

Chapter 9
Connecting the Monitor, Keyboard, Mouse, and UPS
80
3.
Slide the module into the power bay and press the release lever in until it
clicks into place. See Figure 9-5.
Figure 9-5. Installing a Power Supply Module
4.
Plug in the power cord for the power supply module.
See Figure 9-2.
Removing a Power Supply Module
If only one power supply module is used, it must be installed in power supply
bay 2, and a power supply filler panel must be inserted in the empty bay 1.
CAUTION
Operating the HP Netserver without a power supply
filler panel in an empty power supply bay could cause
excessive EMI or thermal damage to the Netserver.
1.
Pinch the release lever on the power supply module and pull on the lever to
slide module out of the power bay. See Figure 9-6.