- HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 1
HP NetServer Product Line Service Reference Guide Volume 2 Mid-Range Version 2 Last Updated: June 2001 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 2
liable for errors contained herein of its software on equipment Server Division 10955 Tantau Avenue MS-45SLE Cupertino, CA 950140770 © Copyright 2000, Hewlett-Packard Company. Audience Assumptions The guide is for HP authorized service personnel who install, administer, and troubleshoot HP NetServers - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 3
Priority DIMM Slot LED Blink Codes Processor Error Codes DIMM Status Error Codes Exploded Views Parts List Keyboards Power Cords Mass Storage Cables Hot-Swap Hard Disk Drive LED Status and Activity Indicators System Board System Switches Specifications HP NetServer LD Pro System Views Control Panel - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 4
Board Connector J6 60 SW1 Switch and Default Settings 61 Memory 62 Video Memory 62 Specifications 62 HP NetServer LH 63 System Views 63 Cover 66 HP NetServer LH Exploded Views 67 HP NetServer LH Parts List 69 Mass Storage Cables 70 HP NetServer LH Plus Exploded Views 71 iv - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 5
Device Priority DIMM Slot LED Blink Codes DIMM Status Error Codes Exploded Views Parts List Keyboards Power Cords Hot-Swap Hard Disk Drive LED Status and Activity Indicators System Board System Switches Specifications HP NetServer LH 4 and LH 4r System Information System Views Front Control Panel - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 6
Channel 126 Boot Problem with Greater than 2 GB HP Disk Array Boot Drive 127 HP C2260A Storage System and the Built-in SCSI Connector 127 Disk Array Controller 127 IDE 240 MB (D1697A) or 270 MB (D2894A) Hard Disk Installation and Configuration 127 Specifications 128 HP NetServer LPr 129 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 7
Control Panel Connector J1 144 Mass Storage Indicator Lights 145 Cover 146 Exploded Views 147 Parts List 149 Keyboards 150 Power Cords 151 Switch Settings on the Hot Swap Subsystem 158 Hot Swap Subsystem SCSI Address Settings 159 Specifications 159 Notes 161 Index 165 vii - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 8
- HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 9
HP NetServer LC System Views Control Panel Line Voltage Selection Switch Power Cable Clamp Keyboard Mouse Serial Port B Serial Port A Video Parallel Port SCSI External Port PCI Slot 6 PCI or EISA/ISA Slot 5 EISA/ISA Slot 1 1 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 10
Front Bezel and Cover System Board IO Panel Connectors Side view Bezel handles Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor External SCSI port 2 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 11
drive cable connector Internal SCSI connector Power P3 & P4 Main fan connector Slot 3 - PCI Slot 2 - PCI Slot 5 - EISA/ISA Control panel cable connector Battery connector Power Adapter (HP Remote Assistant) Pin 1 ROM Mounting pin SW1 system board switches Processor Board Hard disk activity light - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 12
Assistant cable, you will need to remove the jumper on PS REMOTE and PS ON. If you remove HP Remote Assistant from the server, remember to re-install the jumper. WARNING If the HP Remote Assistant is not installed and there is no jumper on PS REMOTE and PS ON, the system will - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 13
interrupt. 7 IO CTRL ENABLE: Enables or disables onboard flexible disk drive controller, IDE controller, and serial and parallel ports. ON: I/O built-in video only if you have a separate video board installed in the server. ON: Enables built-in video. OFF: Disables built-in video. Processor - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 14
memory installed. There are two more banks (four sockets) available for expansion. The maximum memory supported is 192 MB (6 x 32 MB). There are some basic rules to remember when installing SIMMs on the processor board. • The server supports 4 MB and 8 MB (must be 70 ns) and 16 MB and 32 MB (must - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 15
already installed in the server. • If you obtain SIMMs from other sources, for 16 MB and 32 MB SIMMs, the speed must be 60 or 70 ns. Video Memory - DRAM No additional video memory can be installed in the HP NetServer LC. Current video memory is 512 KB. Flexible Disk Drive Guidelines If you - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 16
Description 1 Front bezel 2a 535 MB SCSI HDD 540 MB SCSI HDD 2b 1 GB SCSI HDD 2c 2.1 GB HDD 3 1.44 MB 3.5" Flexible disk drive 4 Mass storage cage 8 7 6 5 4 3 2 1 15 Replacement 5063-5617 D2075-60003 D2386-63001 D2076-63102 D2077-63100 D2035-63004 5063-0397 Exchange D2075-69001 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 17
11l CPU P/133 11m CPU P/166 11n 486 LC/LH Heat Sink 11o P5 Heat Sink 12 Door Assembly 13 32 MB SIMM 70ns * CD-ROM Drive * 3.5" drives 3-pack Hard Disk Tray * 5.25" drives 3-pack Removable Media Trays * DeskDirect Combo HP D2198A HP D2199A J2970-61001 D3353-69001 D3356-69001 D4859-69001 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 18
Fig Description Replacement * DeskDirect NIC * HP Navigator CD-ROM * NS Server Saver Test Disk * Diagnostic Assistant Diskette * This part Power Cords Country Australia/New Zealand Canada/United States Denmark Europe HP Part Number C1405-60301 C1405-60325 C1405-60327 C1405-60330 C3755- - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 19
Specifications Power Supply Power Availability Power Consumption System Dimensions System Weight Operating Altitude Operating Temperature Operating Humidity BTU's Acoustic 100 to 127 VAC ~ 6.0 A or 200 to - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 20
- HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 21
HP NetServer LC 3 System Views Power Switch Keyboard Lock Lock Flexible Disk Drive EIDE CD-ROM Shelf 3 Hot Swap Drive Bay Hot Swap Drive Bay supply. Always disconnect the power cord before removing the cover. Lights green when the NetServer is on. Prevents unauthorized use of the keyboard. Press - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 22
Covers CAUTION The covers are an integral part of the server. The server must be operated with the covers in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 23
system board for memory expansion Follow these simple rules when you plan to install additional memory DIMMs: • Use only HP DIMMs listed on the Technical Reference Label located inside the HP NetServer top cover, in Information Assistant, or in Order Assistant. • DIMMs can be 32 MB, 64 MB, or 128 MB - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 24
disk • Embedded SCSI controller • PCI boards in slots in the following order: 6, 5, 4, 3, 2, 1. • Hard Drive Priority: Allows you to rearrange the order in which hard disk drives are searched for the operating system. All hard disk drives in the system are listed, as well as any bootable ISA board - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 25
²² Processor Error Status Indications Error Condition Voltage Regulator Module for Primary CPU Bad Voltage Regulator Module for Secondary CPU Bad Action Check that primary voltage regulator module (VRM) is correctly seated. If problem Error Codes When no processor error - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 26
Exploded Views 15 14 13 12 2 1 11 10 3 4 7 8 9 5 6 18 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 27
21 22 23 20 19 18 17 16 19 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 28
27 28 29 26 25 24 30 20 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 29
4 Cage Assy, Hot-Swap Mass Storage 5 Light Pipe 6 Backplane PCA, Hot-Swap Cage 7 Hot HDD 12 5 ¼", removable media 13 CD-ROM Drive 14 1.44 MB 3.5" Floppy Disk Drive 15 3.5 inch rail kit 16 Backplane PCA 17 fan 26 Retainer for Adapter Board Guide 27 Guide, Adapter Board Replacement Exchange Not - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 30
5064-1957 * Network Adapter PCA, 100BaseT D5013-63002 * Filler Assy, Hot-Swap 5063-8391 * Upper Drive Filler Panel 5063-8389 * Hot Swap Cage key 5182-4534 * External Battery, 3.6V 1420-0559 ** HP Navigator CD-ROM ** Diagnostic Assistant Diskette * This part is not on the exploded view - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 31
disk drive activity light Yellow or Green = disk drive active CD-ROM drive activity light Green = power on Yellow = drive active Blinking = drawer opening or closing Hot Swap Model Only Hard disk status light Green = drive powered on Flash yellow = drive error All drives flashing simultaneously - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 32
System Board Retaining Latches Primary Processor * J25: 100 MHz Diagnostic LEDs Secondary Processor Socket (Terminator Installed In Dual-Ready Configurations) * Processor Fan * J20: N/C 01 2 3 Primary VRM * J26: N/C 0 1 Memory DIMM Sockets 2 3 * Cable connectors labeled with function. - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 33
Specifications Operating Temperature Non-operating Temperature Operating Humidity (noncondensing) Non-operating Humidity (noncondensing) Operating Altitude Non-operating Altitude Height Width Depth Weight Power supply input voltage - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 34
- HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 35
HP NetServer LD Pro System Views Control Panel Flexible Disk CD-ROM Hot Swap Subsystem Keyboard, mouse, serial, and display connectors External SCSI port connectors 27 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 36
t Yello w = keyb o ard is locked Keyboard Lock Button Power Button Power-On Light Reset Button Hard Disk Activity Light 1 Keyboard Lock Button Keyboard Lock Light Turns the HP NetServer on and off. Note that when the HP NetServer is turned off, the power to the internal circuitry and mass storage - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 37
System Board and Connectors IDE Disk Drive Cable Connector PS4/P4 Flexible Disk J16 9000i PS4 3v Pwr Module J36 AIC 7880 Slot 4 - EISA/ISA Slot 3 - EISA/ISA HP Remote Assistant Connector Battery Connectors Power Supply Cable Connectors SW1 Default Settings: Off On 1 Flash Write Enable - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 38
PS3: J20 P4: J122 PS4: J17 Processor board slot Fast/Ultra SCSI Port A Jumper (No jumper = Ultra) System ROM System Switches Flexible disk drive Mouse Parallel Battery A Battery B Control panel Remote Assistant I2C 1 I2C 2 J24 SCSI Port A Connector Color/Monochrome Power supply on B -3v Power Module - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 39
cable, you will need to remove the jumper on PS REMOTE and PS ON. If you remove HP Remote Assistant from the server, remember to re-install the jumper. HP Remote Assistant Connector WARNING If the HP Remote Assistant is not installed and there is no jumper on PS REMOTE and PS ON, the - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 40
onboard flexible disk drive controller, ON server. ON: Enables built-in video. OFF: Disables built-in video. Memory The processor board in this NetServer problems, equipment problems, or service calls resulting from the use of non-HP DIMMs. Select "Step 5: Save and exit"and follow the instructions - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 41
or Hard memory error Non-HP DIMM installed Inappropriate non-HP-DIMM installed or Hard memory error Hard memory error Action N/A (normal) Reseat the DIMM or Move it to another socket or Replace DIMM N/A (normal) Replace with appropriate HP DIMM or Run Diagnostic Assistant to find the problem Run - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 42
Regulator Module Replace processor board NOTE If the processor overtemperature error is not corrected within a few minutes, the system A 2. PCI slots in the following order: 9, 8, 7, and 6. If you have drives attached to the SCSI A connector, you must change the PCI boot priority order in the - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 43
From an Embedded PCI Controller (SCSI A) Systems with only PCI boards (No EISA or ISA Boards) If you only have PCI boards in your NetServer, your system uses the following default PCI boot priority order: 1. Embedded SCSI A 2. PCI slots in the following order: 9, 8, 7, and 6. Systems with PCI and - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 44
configuration as shipped from HP. NOTE If you are installing Ultra SCSI mass storage devices in this NetServer, you must enable Ultra an optional DAT (Digital Audio Tape) 1 drive that can be installed in upper drive tray 3 or 4. The 2 standard CD-ROM drive is shipped with SCSI ID 5. ID ID - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 45
SCSI Terminator built into cable T IIDDEE C31 System Board 68-Pin to A 50-Pin Adapter Channel 1 Channel 0 PCI DAC Board SCSI A connector C22 Flexible Disk Drive CD-ROM SCSI or IDE Device SCSI or IDE Device I2C B1 (Rear View) C22 Default Switch Settings On Off This is the default SCSI - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 46
control of the hot swap disk module power-on sequence. 6 Reserved Settings Always set to Off Always set to Off On Sets drives to upper eight SCSI addresses. Off Sets drives to lower eight SCSI addresses. On Sets middle shelf in the cage (shelf 2) to SCSI ID 0. Off Sets middle shelf to - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 47
On Off Shelf 1 = ID 9 Shelf 2 = ID 10 Shelf 3 = ID 11 On On Shelf 1 = ID 9 Shelf 2 = ID 8 Shelf 3 = ID 11 Exploded Views 1 8 3 2 4 15 18 16 21 17 19 9 7 20 5 6 10 11 12 13 14 39 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 48
22 25 1 23 32 1 26 28 27 29 43 34 33 40 35 36 37 38 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 49
change after publication. HP's parts price list server under repair. * This part is not on an exploded view. Fig Description 1 Chassis Assembly 2 1.44 MB 3.5" Flexible Disk Drive 3 CD-ROM Drive 7 Upper Drive Slot Cover 8 Hot Swap Cage 9 Hot Swap Cage PCA 10 Hot Swap Light Pipe 11 Hot - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 50
34 Control Panel Bezel 5063-8380 35 Control Panel PCA 5063-0382 36 Card guide Assembly 5063-5697 37 Front Fan 5063-8386 38 Chassis Foot 5042-2122 can be obtained by ordering the HP Cable Kit - Part Number D3588-60001. Only the following HP cables are supported: Cable Diagram C31 C22 A - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 51
-1369 8120-1751 8120-2956 8120-1689 Country India/South Africa Japan Switzerland United Kingdom HP Part Number 8120-4211 8120-4753 8120-2104 8120-1351 Specifications Power Supply Power Availability Operating Temperature Non-Operating Temperature Operating Humidity Non-Operating Humidity Altitude - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 52
Server Footprint System Weight Keyboard Height Width Depth Weight Cable Length Keyboard cable Ventilated Clearance Sides and Top Front Back 369 x 474.71 mm (14.53 x - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 53
HP NetServer LE System Views Control Panel Detail Reset Desktop Position: Lock 54321 SERIAL B SER IAL A SC SI SERIAL B SERIAL A SCSI Mouse Parallel Keyboard Video 45 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 54
Installation View 46 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 55
Exploded View 3 14 1 2 9 4 12 13 15 65 7 11 8 10 HP NetServer LE Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 56
Cover/Bezel Assembly * 3.5" Flexible Disk Rail Mount Kit (3 pack) * Base Assembly * Flexible disk drive cable * Hard disk drive cable * Not on exploded view HP NetServer LE Keyboards Language US Fr-Canada German HP Part Number C1405-60301 C1405-60302 C1405-60303 Exchange D2156-69001 D2152-69001 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 57
French Norway Swiss Swedish UK C1405-60304 C1405-60305 C1405-60309 C1405-60311 C1405-60312 C1405-60313 HP NetServer LE Power Cords Country Australia/New Zealand Canada/United States Denmark Europe HP Part Number 8120-1369 8120-1751 8120-2956 8120-1689 System Board and Connectors Korea/Hangul - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 58
J15 Power Connector J17 Embedded AT (IDE) Controller Hard Drive Connector J19 HD Activity Light J24 CPU Fan Connector (**) J26 Speaker Connection U18 System Board Switches Processors Processor HP or Intel P/N 486/33DX D2169A (HP) OverDrive/33 D2172A (HP) i486DX2/66 A80486DX2-66 SX - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 59
Part Number AAA1M304P-08 9130 MK44C256AP-8 104 V52C104AP-80 9105 HP NetServer LE System Updates These notes reflect changes for the HP NetServer LE which could not be included with the service manual or were changed at a later date. Service manuals are not updated and the information, if any, in - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 60
size is set to 640K, the utility displays only the driver banner with no prompt. The function of this driver does not change the base memory size setting selected in the EISA configuration Utility. Specifications Power Supply Power Availability Power Consumption System Dimensions System Weight - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 61
HP NetServer LF System Views Control panel Mass storage shelf 1 (flexible disk drive) Mass storage shelf 9 Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor External SCSI port Slot 9 - PCI Slot 8 - PCI Slot 7 - EISA/ISA Cover screws (5) Slot 1 - EISA/ISA 53 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 62
Panel Reset button Hard disk activity lights Power-on light Power button 1 2 Reset Keyboard lock light Keyboard lock button Power button Power-on light Reset button Hard disk activity light 1 Hard disk activity light 2 Keyboard lock button Keyboard lock light Turns the server on and off - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 63
Exploded Views 1 4 5 3 2 55 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 64
14 13 12 10 11 16 15 6 9 7 8 56 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 65
may change after publication. HP's parts price list database server under repair. Fig Description 1 LF Cover Assembly 2 LF Chassis foot 3 Power Supply (350w) 4 1.44 MB 3.5" Flexible disk drive 5 1 GB SCSI HDD 5b 3-pack Hard Disk Drive 10 Fan Assembly 11 LF Card Guide Assembly 12 Battery 13 LF - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 66
-60327 C1405-60330 C1414-60001 C1405-60317 C1405-60320 C1405-60321 C1405-60323 Language Danish Fr-Canada German Spanish French Norwegian Swiss Swedish UK HP Part Number C1405-60316 C1405-60302 C1405-60303 C1405-60304 C1405-60305 C1405-60309 C1405-60311 C1405-60312 C1405-60313 Power Cords Language - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 67
Processor Boards New 486/66 Processor Board Cache module installation CPU TYPE DX2 / DX4 J5 DX2D Bank 0 J2 CPU VOLTAGE SELECT DX2/66 DX4/100 Old 486/66 Processor Board J4 MULTI TRIPLE DOUBLE Bank 1/2 Bank 3/4 J4, J5 are in these positions for both DX2/66 and DX4/100 CPU's J1 J2 J3 Bank - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 68
J19-J20 J9, J18, J23 J4 J25 J7 Connector Flexible disk drive Mouse Parallel SCSI port A EISA/ISA slots Fan Remote power supply Control connector is used by the HP Remote Assistant Accessory, a 32-bit EISA Bus Master board used to remotely monitor server functionality. For additional information on - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 69
is controlled by the HP Update Utility). ON: The BIOS can be updated by the HP Update Utility. OFF: CTRL ENABLE: Enables or disables onboard flexible disk drive controller, IDE controller, and serial and parallel ports video board installed in the server. ON: Enables built-in video. OFF: Disables built-in video - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 70
two more banks (four sockets) available for expansion. The maximum memory supported is 192 MB (6 x 32 MB). • The server supports 4 MB, 8 MB, 16 MB, and 32 MB (70 ns server. Video Memory No additional video memory can be installed in the HP NetServer LF. Current video memory is 512 KB. Specifications - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 71
HP NetServer LH System Views Control Panel Flexible Disk CD-ROM Hot Swap Subsystem Keyboard, mouse, serial, and display connectors SCSI port connectors HP NetServer LH Pro 63 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 72
Keyboard, Mouse, serial, and display connectors Keyboard, Mouse, serial, and display connectors SCSI port connectors HP NetServer LH HP NetServer LH Plus SCSI port connectors 64 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 73
The following list describes each item on the control panel. Power Button Power-On Light Reset Button Hard Disk Activity Light 1 Hard Disk Activity Light 2 Turns the HP NetServer on and off. Note that when the HP NetServer is turned off, the power to the internal circuitry and mass storage devices - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 74
Cover CAUTION The cover is an integral part of the server. The server must be operated with the cover in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards. 66 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 75
HP NetServer LH Exploded Views 3a 2 1 13 3b 4a 5 4b 6 8 9 7 10 14 15 16 17 18 TO DISK ARRAY 19 11 12 20 67 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 76
21 1 22 23 24 25 1 27 26 29 30 34 31 32 33 68 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 77
HP NetServer LH Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP inch tray Hot Swap Cage Hot Swap Cage PCA Hot Swap Light Pipe Upper Drive Slot Cover Hot Swap Cage Bezel w/lock Disk module tray - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 78
-63001 D3593-69001 * Hot Swap Cage key 5182-4534 * LH SCSI Cable Kit D3588-60001 * HP Navigator CD-ROM 5063-8343 ** * Diagnostic Assistant Diskette 5011- be obtained by ordering the HP Cable Kit - Part Number D3588-60001. Only the following HP cables are supported: Cable Narrow SCSI (50 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 79
HP NetServer LH Plus Exploded Views 1 2 8 7 15 18 16 17 19 10 9 21 20 3 4 5 11 6 12 13 14 71 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 80
22 24 25 1 23 32 1 28 26 27 29 34 33 72 35 36 37 38 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 81
HP NetServer LH Plus Parts List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP - new color 7 Upper Drive Slot Cover 8 Hot Swap Cage 9 Hot Swap Cage PCA 10 Hot Swap Light Pipe 11 Hot Swap Cage Bezel - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 82
Panel Bezel 5063-8369 5063-8380 35 Control Panel PCA 5063-0382 36 Card guide Assembly 37 Front Fan 5063-5697 5063-8386 38 Chassis Foot 39 Power Management -69001 D4297-69001 D3582-69002 D3583-69002 C3610-69050 HP NetServer LH Plus Mass Storage Cables Cabling Label Location Description C11 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 83
A Intl narrow (50-pin) to wide Fast/wide SCSI adapter (50 5182-4550 Yes (68-pin) adapter pin to 68 pin) B1 I2C cable, system board to hot- 3-pin I2C cable swap backplane 5182-4535 No HP NetServer LH Pro Exploded Views 1 2 8 7 3 4 15 18 16 17 19 10 9 21 20 5 11 6 12 13 14 75 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 84
22 24 25 1 23 40 32 39 26 28 27 29 43 41 42 34 35 33 38 HP NetServer LH Pro Replaceable Parts List 37 36 76 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 85
numbers may change after publication. HP's parts price list database will server under repair. Fig Description 1 Chassis Assembly 2 1.44 MB 3.5" Flexible Disk Drive 3 CD-ROM Drive new color 7 Upper Drive Slot Cover 8 Hot Swap Cage 9 Hot Swap Cage PCA 10 Hot Swap Light Pipe 11 Hot Swap - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 86
Panel Bezel 35 Control Panel PCA 5063-8367 5063-8380 5063-0382 36 Card guide Assembly 37 Front Fan 38 Chassis Foot 5063-5697 5063-8386 5042-2122 D4295-69001 D4296-69001 D4297-69001 D3582-69002 D3583-69002 C3610-69050 HP NetServer LH Pro Mass Storage Cables Labe l C14 C22 A B1 Location Intl - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 87
60320 C1405-60321 C1405-60323 Language Danish Fr-Canada German Spanish French Norway Swiss Swedish UK HP NetServer LH Power Cords Country Australia/New Zealand Canada/United States Denmark Europe HP Part Number 8120-1369 8120-1751 8120-2956 8120-1689 Country India/South Africa Japan Switzerland - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 88
EISA/ISA Slot 2 - EISA/ISA Slot 1 - EISA/ISA I 2 C Connectors SCSI Port B Connector SCSI Port A Connector HP NetServer LH System Board Connectors, Switches, and Jumpers Connector IDE disk drive Keyboard Video Serial SCSI port B PCI slots Fans Power supply on Power supply Processor board Number - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 89
J36 AIC 7880 AIC 7880 J29 Slot 4 - EISA/ISA Slot 3 - EISA/ISA Slot 2 - EISA/ISA Slot 1 - EISA/ISA I2C Bus HP NetServer LH Plus / LH Pro System Board Connectors Connector IDE disk drive cable Keyboard Serial (2) Video SCSI port B PCI slots Fans A, B Number J9 J1 J2 J3 J32 J10 - J14 J34, J35 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 90
J16 J27 J21 SW1 U39 Remote Assistant Connector - J22 (LH) and J25 (LH Plus/LH Pro) This connector is used by the HP Remote Assistant Accessory, a 32-bit EISA Bus Master board used to remotely monitor server functionality. When you install the HP Remote Assistant cable, you need to remove the jumper - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 91
5 6 7 8 LH Flash Write Enable Boot Lock Disable Config Valid Config Unlock Password Enable SMI # Enable IO Control Enable Video Enable Function FLASH WRITE ENABLE: Enables or disables one of the two levels of flash ROM write protection (the other level of protection is controlled by the HP Update - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 92
not cover performance problems, equipment problems, or service calls resulting from the use of non-HP DIMMs. LH Plus/Pro Processor Board LED Blink Codes The Processor board in the NetServer LH Plus or Pro contains LEDs that can indicate memory errors and processor errors. When a memory error exists - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 93
viewed through the NetServer's rear panel cooling perforations. Diagnostic LEDs: DIMM 3 DIMM 2 DIMM 1 DIMM 0 Memory Error Codes LED Code Off Definition No DIMM installed or Non-EEPROM DIMM installed On Flash HP DIMM installed Inappropriate HP DIMM installed or Hard memory error Blink Double - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 94
If the processor overtemperature error is not corrected within priority: 1. CD-ROM drive (if a bootable CD-ROM is installed) 2. Flexible disk drive 3. IDE device 4. SCSI Exit and save the configuration. Cabling Configurations The HP NetServer comes in two standard models that can be reconfigured - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 95
Duplex, non-disk array model with internal controller (standard model) External terminator T built into cable IDE C1 Flexible Disk Drive CD-ROM SCSI or IDE Device System Board Internal terminator I2C built into board SCSI B SCSI A C5 C5 T Hot Swap Subsystem Off On UPPER CAGE 1 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 96
Non-duplex, disk array model with PCI controller board (standard model) or EISA controller board Flexible Disk External terminator T built into cable Drive CD-ROM IDE SCSI or IDE Device System Board Internal terminator PCI/EISA Board built into I2C board SCSI B SCSI A C2 C6 T C4 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 97
Configuring Switch Settings on the Hot Swap Subsystem Switch setting combinations are given in the table below. Off On 1 2 3 4 UPPER 5 CAGE 6 1 2 LOWER 3 CAGE 4 5 6 Switch 1 2 3 4 5 6 Function I2C Bus Setting I2C Bus Setting High/Low Addresses SCSI Address Zero Sets middle shelf - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 98
drive, see the Technical Information Label on the CD-ROM drive. ID 0 Shelf 6 = ID 6 Specifications Power Supply Power Availability Power Consumption LH/LH Plus 350W continuous, 386W peak LH Pro 450W continuous LH/LH Plus: 499/479W maximum with 110/220V supply 551/528W peak with 110/220V supply LH - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 99
HP NetServer LH 3 and LH 3r System Views Front Control Panel Control Description Lock (LH 3 only) Locks system to prevent unauthorized use. DC Power Switchand indicator light Turns the NetServer on and off. This switch is behind the protective door on the front panel. Push once to turn on, again - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 100
Resets the NetServer from internal ROM. This switch is behind the protective door on the front panel. Keyboard lockand indicator light Locks system Red = Problem detected Front Panel Menu, as Shown on Status Screen System Information Reports system hardware details and software version numbers. - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 101
Rear View Remote Management Port Serial B Port Serial A Port Parallel Port Mouse Port Keyboard Port Monitor Port Power Supplies Power Connector Covers (LH 3) Cover 1 Cover 2 Cover 3 Covers (LH 3r) Cover 2 Cover 1 Cover 3 Cover 1 Cover 2 Cover 3 93 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 102
a maximum capacity of 1 GB of RAM. • The minimum memory configuration for the NetServer LH 3/LH 3r is one 128 MB DIMM. • The system board DIMM sockets are numbered from the following order: 1. IDE CD-ROM drive with a bootable CD-ROM. 2. Flexible disk drive with a bootable flexible disk. 3. Embedded - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 103
LED LED 01 23 LED Error Codes Error Condition Corrective Action Primary VRM Failure Check that primary voltage regulator module (VRM) is correctly seated. If problem persists, replace VRM. Secondary and OFF at 1 Hz in 90/10 proportion of time: non-HP DIMM installed • ON: HP DIMM installed 95 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 104
Exploded Views 29 30 17 18 15 16 12 13 10 1 30 4 6 5 7 3 96 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 105
2 28 31 32 27 26 29 42 43 44 41 34 38 40 14 41 39 97 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 106
plate Hot-swap tray, half-height Hot-swap tray, low-profile Non-hot-swap tray, hard disk drive (3 ea.) Non-hot-swap tray, removable media device (2 ea.) 4.2 GB Ultra/Wide SCSI drive, 7200 rpm (for non-hotswap use) 9.1 GB Ultra/Wide SCSI drive, 7200 rpm (for non-hotswap use) 9.1 GB low-profile Ultra2 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 107
Fig Description Replacement Exchange 28 Fan assembly, rear chassis 5064-3553 29 Fan assembly, power supply 5064-3538 30 Fan assembly, CPU 5064-3531 31 Power supply module, 300W 5064-6603 32 Power supply cage 5064-6605 5064-6604 33 Battery 3V 1420-0356 34a Front panel assembly, - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 108
India/South Africa Japan Switzerland United Kingdom Part Number 8120-4211 8120-4753 8120-2104 8120-1351 Hot-Swap Hard Disk Drive LED Status and Activity Indicators Each hot-swap hard disk drive module has two LED apertures on its front, one for power status and one for activity status, as shown - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 109
OFF OFF OFF 2 OFF OFF ON ON 3 ON ON OFF OFF 4 OFF ON OFF ON Note: Only processor speeds for the 100 MHz bus are supported. 101 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 110
Specifications Operating Temperature Non-operating Temperature Operating Humidity ). Follow local safety regulations, and use one person for every 40 pounds (18 kg) of NetServer weight when lifting it. Weight and Dimensions LH 3r Height 354.7 mm (14 in) Width 482.6 mm (19 in) Depth 749.2 mm - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 111
HP NetServer LH 4 and LH 4r System Information System Views HP NetServer LH 4 (Pedestal) HP NetServer LH 4r (Rack-Optimized) Front Control Panel Control Description Lock (LH 4 only) Locks system to prevent unauthorized use. DC Power Switchand indicator light Turns the NetServer on and off. This - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 112
Resets the NetServer from internal ROM. This switch is behind the protective door on the front panel. Keyboard lockand indicator light Locks system Red = Problem detected Front Panel Menu, as Shown on Status Screen System Information Reports system hardware details and software version numbers - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 113
Rear View Remote Management Port Serial B Port Serial A Port Parallel Port Mouse Port Keyboard Port Monitor Port Power Supplies Power Connector Covers (LH 4) Cover 1 Cover 2 Cover 3 Cover 2 Cover 1 Cover 3 105 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 114
Covers (LH 4r) Cover 1 Cover 2 Cover 3 Memory The two memory boards (Memory A and Memory B) are located on the system board assembly, beneath the memory cage cover. Both - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 115
port Mouse port Keyboard port Monitor port VRM 1 VRM 2 Note: Processor slots without processors have terminators. NOTE Use only HP DIMMs listed in HP Information Assistant or HP Order Assistant. Keys Notches Keys Latches CAUTION Do not rock the DIMM into place, but apply firm and even - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 116
with bootable CD-ROM ◊ Flexible Disk with bootable flexible disk ◊ Hard Drive • Hard Drive Priority: Allows you to rearrange the order in which hard disk drives are searched for the operating system. All hard disk drives in the system are listed, as well as any bootable ISA board. Boot order for - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 117
19 30 17 18 15 16 12 13 10 2 28 31 32 27 26 29 109 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 118
. Fig 1 2 3 4 5a 5b 6 7a 7b 8 9 10 11 Description System board PCA (PCA only) I/O PCA Memory PCA Backplane PCA Pentium II Xeon 400MHz/512K processor Pentium II Xeon 400MHz/1MB processor Voltage Regulator Module (VRM) Memory DIMM, 64MB Memory DIMM, 256MB Memory cover Processor cover Hot-swap mass - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 119
rpm (hot-swap use) 18.2 GB half-height Ultra2 drive, 7200 rpm (hot-swap use) 1.44MB 3.5" floppy drive Accessory board guide Fans (2), w/accessory board guide assy. Fan assembly, rear chassis Fan assembly, power supply IDE CD ROM drive Power supply module, 300W Power supply cage Front panel assembly - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 120
Fig Description Replacement Exchange * Floppy cable 5183-3443 * SCSI (wide) cable, internal 68-50 pin 5183-3444 * SCSI cable, internal 5183-3445 * SCSI cable, internal to external 5183-3446 * Battery 3V 1420-0356 * Installation handles, rack version (4) 5002-5191 * Rails for - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 121
LED Status and Activity Indicators Each hot-swap hard disk drive module has two LED apertures on its front, one for power status and one for activity status. System Board VRM 3/4 Memory Board B Memory Board A VRM 1/2 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 122
below) On = Clear config On = Clear p/w Always off Always off Processor Speed: 400 450 500 Switch 2: ON OFF ON Switch 4: ON ON OFF Note: Only processor speeds for the 100 MHz bus are supported. Cabling R1 Remote Management Rear Panel 1 2 I/O Board C73 SCSI knockouts Control Panel C72 SE - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 123
Cable 5183-3448 5183-3449 5183-2413 * Optional cable Specifications Temperature Operating Non-operating 5°to 35°C (41°to 95 2.5 cm (1.0 in) 15 cm (6.0 in) Weight and Dimensions - LH 4 NOTE A fully-loaded NetServer can weigh up to 160 pounds (73 kg). Follow local safety regulations, - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 124
Height Width Depth Weight 494.8 mm (19.5 in) 350.5 mm (13.8 in) 724.2 mm (28.5 in) 35 - 50 kg (77 - 110 lb) Weight and Dimensions - LH 4r Height Width Depth Weight 354.7 mm (14 in) 482.6 mm (19 in) 749.2 mm (29.5 in) 36 - 60 kg (79 - 132 lb) Power Supply - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 125
HP NetServer LM System Views Front and Rear Views Control Panel Re se t 1 2 Shelf 1 Mass Storage Device Shelves Shelf 9 AC power AC line select switch Padlock or cable lock hole NOTE: Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Built-in video External SCSI Port The server - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 126
Control Panel Power-on Light Power Button Reset Button Hard Disk Activity 1 Hard Disk Activity 2 Keyboard Lock Light Keyboard Lock LCD Exploded View 1 2 4 3 5 118 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 127
2 16 15 14 17 13 12 9 6 7f 10 7 8 11 119 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 128
. Part numbers may change after publication. HP's parts price list database will generally contain board, any added accessory boards, and keep them with the server under repair. Fig Description 1 Cover 3 Power Supply 4 * ECC Memory Board * HDD Activity Light Cable * Cable for 2 Fans * - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 129
Processor Board 66Mhz * 3-pack Hard Disk Drive Trays, 3.5" * 3-pack Removable Media Trays, 5.25" * Not on exploded view Disk Array Parts Insert/Backplane assembly SCSI Internal Cable PC Array Controller 510 MB Disk Module assembly 1 GB Disk Module assembly HP NetServer LM Keyboards Language US - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 130
HP NetServer LM Power Cords Country Australia/New Zealand Canada/United States Denmark Europe HP Part Number 8120-1369 8120-1751 8120-2956 8120-1689 System Board Country India/South Africa Japan Switzerland United Kingdom HP Part Number 8120-4211 8120-4753 8120-2104 8120-1351 Video memory DRAM - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 131
video is disabled. Disable the built-in video only if a separate video board is installed in the server. Floppy R/W. When the jumper is on pins 1 and 2, it disables writing to flexible disk drives. NVRAM Clr. When the jumper is on pins 2 and 3, it erases the current system configuration from NVRAM - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 132
from certain manufacturers have been tested for compatibility with the HP NetServer LM Series. Hewlett-Packard does not supply the DRAM upgrade. Consult the HP PC Bulletin Board Service at 1-408-553-3500 for a current list of supported DRAM upgrades. Recommended Video DRAM Vendors Vendor Fujitsu - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 133
at a later date. Service manuals are not updated and the information, if any, in this section is the latest information available. See also the HP NetServer LM Update, HP Part No. D2332-90009, for additional information on operating systems. Factory Installed SCSI Hard Drive Some LM models have - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 134
HP D2649A or D1681A) may cause a "Shadow RAM diagnostic failed" error "YES." Otherwise, the server will not treat that HP NetServer #1 diskette, version F.01.00, you may select Channel A (external) or Channel B (internal) to be the primary SCSI channel. The system first looks for the boot drive - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 135
Storage System to the embedded Fast SCSI-2 subsystem, use the HP Fast SCSI-2 Kit (C3607A). The kit contains an active terminator, driver software, and installation instructions to support the HP Storage System on the embedded Fast SCSI-2 subsystem. Disk Array Controller Use the EISA Array Controller - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 136
Hard Drive 1 (or 2) to be Drive Type 2 or 48 (User Definable) at the end of the list of choices for any IDE hard disk drives installed. Do not use Hard Disk Auto Configuration. Verify these parameters as the drive is Enabled, the drive operates very slowly. Specifications Power Supply Power - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 137
HP NetServer LPr System Views Front Panel Controls CD-ROM Drive Drive Activity LED Reset Switch Power ON/OFF LED Power On/Off Switch Drive Error LED Hot Swap Drive Shelf SCSI ID #0 Hot Swap Drive Shelf SCSI ID #1 Fan Failure LED Over-temperature LED Floppy Disk Drive Power ON/OFF Switch - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 138
drive before replacing it. NOTE: You may have to remove the front bezel to see the specific drive LEDs and determine which device is in trouble power down the system and correct the fan problem. This indicator reports on the power supply fan adapter is supporting transfers at the 100 mbps (million bits - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 139
with 5V SDRAM DIMMs (Dual In-Line Memory Modules). The NetServer LPr ships with at least 64 MB of main memory and supports up to 1 GB. Memory is available in the following DIMM numerical order: 1, 2, and 3. Use only HP DIMMs. System Board DIMM Socket 0 DIMM Socket 1 DIMM Socket 2 DIMM Socket 3 131 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 140
Retaining Clips Video Memory The HP NetServer LPr comes standard with a 1 MB frame buffer to support video displays of 1024 (horizontal pixels) x768 (vertical lines) x 256 (colors per pixel) at refresh rates up to 72 Hz. You can upgrade the frame buffer to 2 MB to support 1280 x 1024 by adding two - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 141
Boot Device Priority By default, the HP NetServer searches for bootable devices in the order shown below. CD-ROM Drive Floppy Disk Drive Embedded SCSI Controller, starting with SCSI ID 0 PCI Slots in the order 3, 2, and 1 On each controller, the server scans for a boot device starting at device ID 0 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 142
it into the slot. Check to make sure you removed any handles or board extenders. Remote Control Card Refer to the Top Tools Administration Guide for Remote Control along with the upgrade kit documentation for information on the remote control card. Route cable through open spaces to PCI area. DO - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 143
HP NetRAID Card NOTE If there are other SCSI controllers on the PCI bus, the slot will affect boot order. See the Boot Device Priority. SCSI Cable SCSI Repeater Card HP NetRAID Adapter SCSI Cable 135 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 144
I/O Board SCSI Cable Connector Embedded SCSI Connector Terminator Block 136 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 145
Module Slot Primary Processor Module CPU Processor Switch Primary Processor VRM 350 MHz OFF ON 1 2 3 4 400 MHz OFF ON 1 2 3 4 450 MHz OFF ON 1 2 3 4 500 MHz OFF ON 1 2 3 4 550 MHz OFF ON 1 2 3 4 NOTE NOTE: Only the first 4 switches set the processor clock. If you have two modules in your - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 146
Processor Module Do not touch VRM components VRM Secondary VRM Slot Secondary Processor Slot NOTE Be sure that the VRM and the processor module associated with it are both in primary or secondary slots. Exploded Views 138 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 147
kit 7 Hot-swap bay filler panel 8 Floppy disk drive 9 Control panel 10 CD-ROM drive, Slimline 11 LPr chassis 12 Processor terminator card 13a Pentium II, 400 MHz 13b Pentium II, 450 MHz 13c Pentium II, 500 MHz 13d Pentium II, 550 MHz 13e Pentium II, 600 MHz Replacement Exchange 5064 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 148
22 PCI access door 23 Power supply 24 Bezel kit (HP pictured) Bezel kit, 3rd party 25 System board Cables Cable SCSI Terminator Power I2C Management Port IDE, CD-ROM Control panel Floppy drive SCSI AC internal External SCSI/Riser Terminal D1134-63001 D1134-69001 the server under repair. 140 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 149
A Port Connector Parallel Port Connector Mouse Connector Keyboard Connector Monitor Connector System Switches System Switches Default Settings CPU Frequency (MHz) 350 400 450 500 550 Off On Off On Off On Off On Off On On Off Must Be OFF (7 & 8) On = Clear Password (6) On = Clear Config (5) On - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 150
Thermal Output Maximum Operating 1041 BTU/hr Minimum Clearance No requirement in HP racks. Weight and Dimensions Weight Width Depth Height Approx. 40 lbs 28 inches (71.1cm) 3.5 inches (8.9 cm) Power Supply Specifications Type Input - Max. ROapnegraeting Current In-rush Current Operating - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 151
HP NetServer LS System Views Front View Cover keylock Key bag Rear View 143 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 152
Light Reset Button Hard Disk Activity Light 1 Hard Disk Activity Light 2 Keyboard Lock Button Keyboard Lock Light LCD Turns the NetServer on and off. Note that when the NetServer you remove HP Remote Assistant from the server, remember to re-install the jumper. WARNING If the HP Remote Assistant - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 153
Mass Storage Indicator Lights Control Panel J1 For some SCSI controller boards, you must connect the hard disk activity light. 145 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 154
disk activity light 1 connector Hard disk activity light 2 connector Cover CAUTION The cover is an integral part of the NetServer. The NetServer must be operated with the cover in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 155
Exploded Views 1 2 9 13 12 10 14 11 4 3 5 15 19 18 17 16 6 7 8 147 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 156
25 26 1 27 20 21 22 23 24 1 33 28 32 29 30 31 148 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 157
them with the server under repair. Fig Description 1 Chassis Assembly 2 Hot Swap Cage 3 Hot Swap Cage PCA 4 Hot Swap Light Pipe 5 Hot HDD 19 1.44 MB 3.5" Flexible Disk Drive 20 LS System Board 21 HP SCSI PCI Controller Board 22 PCB Support Rail Replacement not orderable 5063-5671 5063 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 158
5635 29 Chassis Foot 5041-1082 30 Fan Assembly 3160-1004 31 Card Guide Plastic Assembly 5041-6342 32 LS Control Panel PCA 5064-0739 33 LS * Video DRAM ** 5182-9404 * LS SCSI Cable Kit D3330-60010 * HP Navigator CD-ROM*** 5063-8346 * Diagnostic Assistant Diskette 5011-1941 * This - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 159
Storage Cables If you need additional cables, the cables are not available separately, but only by ordering the HP Cable Kit Part Number D3330-60010. Only the following HP cables and adapter are supported: Cabling Label C1 C2 C3 C4 C5 A Cable Narrow SCSI (50 pin) cable with built-in terminator - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 160
System Board IO Panel Connectors Side view Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor Flexible Disk 1.44 MB Power Control Enable Disable Boot Block Disable E n ab le Program Boot Block Disable E n ab le Video Sleep REG 46E8 REG 3C3 Video DRAM Upgrade PCI 1 PCI 2 Shared - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 161
Hard Disk Activity Number J9F1 J9A1 J7A1 J8A1 J0G2 P2-2, P2-1 P1-1, P1-2, P1-3 J1J1, J4J3 PS3 (J9B2) PS4 ((J9C2 PS1-PS2 (J9O2) MEM 1 - J9J1 MEM 2 - J8J1 J9E1 J1J2, J4J2 Connector Flexible disk drive is used to boot the server from drive A if the BIOS gets corrupted service technician update the boot - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 162
SIMMs within a bank must be the same size. Bank 3 Bank 2 Bank 1 Bank 3 Bank 2 Bank 1 When installing additional memory, note the following: • The following HP SIMMs are supported: Type 4 MB SIMM (70 ns) 8 MB SIMM (70 ns) 16 MB SIMM (70 ns) 32 MB SIMM (70 ns) Product Number D2974A D3577A D2297A - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 163
of internal video memory. The internal, integrated Cirrus super VGA controller is fully compatible , 40-pin SOJ package DRAM allows the controller to support 132-column text modes and high resolution graphics. Boot (where the BIOS will search for the boot drive) is set by the slot location where the - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 164
Duplex, non-disk array model with internal controller (standard model) External terminator T built into cable IDE C1 Flexible Disk Drive CD-ROM SCSI or IDE Device System Board Internal terminator I2C built into board SCSI B SCSI A C2 C2 T Hot Swap Subsystem Off On UPPER CAGE 1 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 165
board (standard model) Flexible Disk External terminator T built into cable Drive CD-ROM IDE C1 SCSI or IDE Device 68 to 50 pin adapter The standard model includes a PCI controller board. The CD-ROM drive is set for SCSI ID 5. To change the SCSI addresses, see Configuring Switch Settings on - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 166
Sets drives to upper eight SCSI addresses. Note: this setting may cause time-out problems with your NOS due to delayed start. Off Sets drives to -on sequence is determined by the disk array controller. Not supported by HP SCSI controller boards. 6 Upper/Lower Cage On Lower cage Identifies - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 167
changing the SCSI address setting on the CD-ROM drive, see the Technical Information Label on the CD-ROM drive. Upper Cage Switch Settings SCSI Address 3 - 12 Shelf 5 = ID 8 Shelf 6 = ID 14 Specifications Power Supply Power Availability Power Consumption System Dimensions System Weight Operating - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 168
- HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 169
Notes 161 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 170
162 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 171
163 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 172
164 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 173
, 155 BTU's LC, 11 C Cable Kit LD, 42 LH, 70 cables LD ordering, 42 LH ordering, 70 LH Plus, 74 LH Pro, 78 LS configurations, 155 LS mass storage, 151 Cables LPr, 140 cables and part numbers LH4, 115 cabling configurations LH4, 114 CD-ROM drive SCSI address setting LH, 90 LS, 159 CMOS Clear LS, 154 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 174
Light LS, 144 hard disk drive LED LH3, 100 Hard Disk Drive LED Status LH4, 113 166 hot swap subsystem SCSI address switch settings LD, 38 LH, 90 LS, 159 hot swap subsystem switch settings LS, 158 HP C2260A Storage System, 127 HP Disk Array 2 GB disk LM, 127 HP NetRAID Card LPr, 135 HP NetServer - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 175
Keyboard Lock Light LS, 144 keyboards LC, 10 LC 3, 22 LD, 43, 44 LE, 48 LF, 58 LH, 79 LH3, 99 LH4, 112 LH4, 106 LM, 124 LPr, 131 maximum LF, 62 memory configuration LC 486 processor board, 6 LC Pentium processor board, 6 LD, 32 LE, 51 LF, 62 LH, 84 LH Plus/Pro, 84 LS, 154 memory error codes LD, 33 LH - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 176
power cords LC, 10 LC 3, 22 LD, 43 LE, 49 LF, 58 LH, 79 LH3, 100 LH4, 112 LM, 122 power supply LC, 11 LD, 43 LE, 52 LF, 62 LH, 90 LH3, 102 LH4, 116 LM specs, 128 LS, 159 Power-On Light LS, 144 Processor LPr, 137 processor boards LC, 5 Processor Boards LF, 59 - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 177
LM note, hard drive, 125 LM selecting primary channel, 126 SCSI address setting for CD-ROM drive LH, 90 LS, 159 SCSI address switch settings LD, 38 LH, 90 LS, 159 SCSI cabling configurations LD, 36 LH, 86 LS, 155 SCSI port LM connector location, 117 serial port LM connector locations, 117 server LE - HP LH4r | HP Netserver Service Handbook, Volume 2 - Mid - Page 178
LD, 43 LF operating, 62 LH, 90 LH3, 102 LH4, 115 LM operating, 128 operating LE, 52 Temperature LPr, 142 V video LC installing DRAM, 7 LE type of DRAM needed, 51 LF installing DRAM, 62 LM