HP LH4r HP Netserver Service Handbook, Volume 2 - Mid - Page 97
Switch, Function, Settings
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Configuring Switch Settings on the Hot Swap Subsystem Switch setting combinations are given in the table below. Off On 1 2 3 4 UPPER 5 CAGE 6 1 2 LOWER 3 CAGE 4 5 6 Switch 1 2 3 4 5 6 Function I2C Bus Setting I2C Bus Setting High/Low Addresses SCSI Address Zero Sets middle shelf in cage to SCSI ID 0. Remote Start Determines control of the hot swap disk module power-on sequence. Upper/Lower Cage Identifies cage location. This is important information for the SCSI addresses and for the I2C bus. Settings Always set to Off Always set to Off Always set to Off On: Sets middle shelf in the cage (shelf 2 or shelf 5) to SCSI ID 0. Off: Sets middle shelf to normal SCSI address sequence. See SCSI Address Settings table below for description of settings. On: Internal control: Upper cage is set to delayed start and lower cage is set to power-on at startup. Off: Power-on sequence is determined by the disk array controller. On: Lower cage Off: Upper cage See SCSI Address Settings table below for description of settings. 89