HP LH4r HP Netserver Service Handbook, Volume 2 - Mid - Page 46
Hot Swap Subsystem SCSI Address Settings
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
On Off 1 2 3 4 5 6 Technical Information Label with configuration information Always set switches 1, 2 and 6 to Off. Switch 1 2 3 4 Function I2C Bus Setting I2C Bus Setting High/Low Addresses Sets SCSI addresses for upper or lower eight addresses Set to Off if not using Fast-Wide (68 pin) SCSI SCSI Address Zero Sets middle shelf in hot-swap cage to SCSI ID 0. 5 Remote Start Determines control of the hot swap disk module power-on sequence. 6 Reserved Settings Always set to Off Always set to Off On Sets drives to upper eight SCSI addresses. Off Sets drives to lower eight SCSI addresses. On Sets middle shelf in the cage (shelf 2) to SCSI ID 0. Off Sets middle shelf to SCSI ID 2. On Internal control: cage is set to delayed start. Recommended setting. Always set to Off Hot Swap Subsystem SCSI Address Settings Switches 3 and 4 determine the SCSI address setting for each shelf in the hot swap subsystem. The table below lists the possible SCSI addresses for each shelf. NOTE For information on changing the CD-ROM drive SCSI address setting, see the Technical Information Label on the CD-ROM drive. Hot-Swap Shelf SCSI Address Settings Switch 3 4 SCSI Address Off Off Shelf 1 = ID 1 Shelf 2 = ID 2 Shelf 3 = ID 3 Off On Shelf 1 = ID 1 Shelf 2 = ID 0 Shelf 3 = ID 3 38