HP ProLiant DL380 ProLiant DL380 Generation 2 Server Maintenance and Service G - Page 76

CD MultiBay Cable, Removing the CD MultiBay cable

Page 76 highlights

Removal and Replacement Procedures CD MultiBay Cable To remove the CD MultiBay cable: 1. Power down the server. See the "Powering Down the Server" section in this chapter. 2. Extend or remove the server from the rack. See the "Preparation Procedures" section in this chapter. 3. Remove the access panel. See the "Access Panel" section in this chapter.  4. Disconnect the CD MultiBay cable from the SCSI backplane .  5. Disconnect the CD MultiBay cable from the CD MultiBay adapter board . 2 1 Figure 2-57: Removing the CD MultiBay cable Reverse steps 1 through 5 to replace the CD MultiBay cable. 2-62 Compaq ProLiant DL380 Generation2 Server Maintenance and Service Guide COMPAQ CONFIDENTIAL Codename: Magna Part Number: 203840-003 Last Saved On: 1/28/02 1:12 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Removal and Replacement Procedures
2-62
Compaq ProLiant DL380 Generation2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL
Codename: Magna Part Number: 203840-003 Last Saved On: 1/28/02 1:12 PM
CD MultiBay Cable
To remove the CD MultiBay cable:
1.
Power down the server. See the
Powering Down the Server
section in this chapter.
2.
Extend or remove the server from the rack. See the
Preparation Procedures
section in
this chapter.
3.
Remove the access panel. See the
Access Panel
section in this chapter.
4.
Disconnect the CD MultiBay cable from the SCSI backplane
.
5.
Disconnect the CD MultiBay cable from the CD MultiBay adapter board
.
1
2
Figure 2-57:
Removing the CD MultiBay cable
Reverse steps 1 through 5 to replace the CD MultiBay cable.