HP ProLiant DL380 ProLiant DL380 Generation 2 Server Maintenance and Service G - Page 80
Optional Remote Insight LightsOut Edition Interface Cable, Compaq ProLiant DL380 Generation 2
View all HP ProLiant DL380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
Removal and Replacement Procedures Optional Remote Insight Lights-Out Edition Interface Cable To remove the Remote Insight Lights-Out Edition interface cable: 1. Power down the server. See the "Powering Down the Server" section in this chapter. 2. Extend or remove the server from the rack. See the "Preparation Procedures" section in this chapter. 3. Remove the access panel. See the "Access Panel" section in this chapter. 4. Remove the PCI riser cage. See the "PCI Riser Cage" section in this chapter. 5. Disconnect the Remote Insight Lights-Out Edition interface cable from the PCI riser board . 6. Disconnect the Remote Insight Lights-Out Edition interface cable from the Remote Insight Lights-Out Edition expansion board . 2 1 Figure 2-61: Removing the Remote Insight board interface cable (PCI expansion board ejector/divider removed for clarity) Reverse steps 1 through 6 to replace the Remote Insight Lights-Out Edition interface cable. For more information about this option, refer to the Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide and the Compaq Remote Insight Lights-Out Edition User Guide. 2-66 Compaq ProLiant DL380 Generation2 Server Maintenance and Service Guide COMPAQ CONFIDENTIAL Codename: Magna Part Number: 203840-003 Last Saved On: 1/28/02 1:12 PM