HP ProLiant DL380 ProLiant DL380 Generation 2 Server Maintenance and Service G - Page 80

Optional Remote Insight LightsOut Edition Interface Cable, Compaq ProLiant DL380 Generation 2

Page 80 highlights

Removal and Replacement Procedures Optional Remote Insight Lights-Out Edition Interface Cable To remove the Remote Insight Lights-Out Edition interface cable: 1. Power down the server. See the "Powering Down the Server" section in this chapter. 2. Extend or remove the server from the rack. See the "Preparation Procedures" section in this chapter. 3. Remove the access panel. See the "Access Panel" section in this chapter. 4. Remove the PCI riser cage. See the "PCI Riser Cage" section in this chapter. 5. Disconnect the Remote Insight Lights-Out Edition interface cable from the PCI riser board . 6. Disconnect the Remote Insight Lights-Out Edition interface cable from the Remote  Insight Lights-Out Edition expansion board . 2 1 Figure 2-61: Removing the Remote Insight board interface cable (PCI expansion board ejector/divider removed for clarity) Reverse steps 1 through 6 to replace the Remote Insight Lights-Out Edition interface cable. For more information about this option, refer to the Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide and the Compaq Remote Insight Lights-Out Edition User Guide. 2-66 Compaq ProLiant DL380 Generation2 Server Maintenance and Service Guide COMPAQ CONFIDENTIAL Codename: Magna Part Number: 203840-003 Last Saved On: 1/28/02 1:12 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Removal and Replacement Procedures
2-66
Compaq ProLiant DL380 Generation2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL
Codename: Magna Part Number: 203840-003 Last Saved On: 1/28/02 1:12 PM
Optional Remote Insight Lights-Out Edition Interface Cable
To remove the Remote Insight Lights-Out Edition interface cable:
1.
Power down the server. See the
Powering Down the Server
section in this chapter.
2.
Extend or remove the server from the rack. See the
Preparation Procedures
section in
this chapter.
3.
Remove the access panel. See the
Access Panel
section in this chapter.
4.
Remove the PCI riser cage. See the
PCI Riser Cage
section in this chapter.
5.
Disconnect the Remote Insight Lights-Out Edition interface cable from the PCI riser
board
.
6.
Disconnect the Remote Insight Lights-Out Edition interface cable from the Remote
Insight Lights-Out Edition expansion board
.
2
1
Figure 2-61:
Removing the Remote Insight board interface cable
(PCI expansion board ejector/divider removed for clarity)
Reverse steps 1 through 6 to replace the Remote Insight Lights-Out Edition interface cable.
For more information about this option, refer to the
Compaq ProLiant DL380 Generation 2
Server Setup and Installation Guide
and the
Compaq Remote Insight Lights-Out Edition User
Guide
.