Appendix A Event Codes Pager Code 21210 21211 21212 21213 21214 21215 21216 21217 21218 21219 21220 21221 21222 21232 21233 21234 21235 21236 21237 21238 21239 21240 21241 21242 21301 21320 21321 21322 21323 21324 21325 Server Event Severity NetRAID: Logical drive consistency check operation aborted WARNING NetRAID: Logical drive inconsistencies found and corrected WARNING NetRAID: Logical drive consistency check operation failed CRITICAL NetRAID: Logical drive reconstruction started INFORMATIONAL NetRAID: Logical drive reconstruction completed INFORMATIONAL NetRAID: Logical drive reconstruction failed CRITICAL NetRAID: Physical drive predictive failure event occurred CRITICAL NetRAID: Physical drive predictive failure event occurred WARNING NetRAID: Abnormal end to SCSI operation INFORMATIONAL NetRAID: New drive inserted INFORMATIONAL NetRAID: Backup battery module is missing or disconnected WARNING NetRAID: Backup battery module voltage is Low WARNING NetRAID: Backup battery module temperature is high WARNING HP Disk Array: Write cache error CRITICAL HP Disk Array: Logical drive critical WARNING HP Disk Array: Logical drive not available CRITICAL HP Disk Array: Hot spare disk failed WARNING HP Disk Array: Hot spare replacement succeeded INFORMATIONAL HP Disk Array: Hard disk failure WARNING HP Disk Array: SCSI bus parity error threshold exceeded WARNING HP Disk Array: Bad sector threshold exceeded WARNING HP Disk Array: Disk array controller hardware error threshold exceeded WARNING HP Disk Array: Miscellaneous error threshold exceeded WARNING HP Disk Array: Time to replace disk array controller INFORMATIONAL The installed LAN adapter no longer matches the configuration information stored about it. WARNING The LAN adapter has detected a number of receive errors higher than WARNING the threshold level. The LAN adapter has detected a number of transmit errors higher WARNING than the threshold level. The LAN adapter installed in the server has reset itself. CRITICAL The LAN adapter has detected a network protocol problem. WARNING The LAN adapter has detected a packet length error. WARNING The LAN adapter has detected a number of packet length errors higher than threshold level. WARNING 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

Appendix A
Event Codes
Pager
Code
Server Event
Severity
21210
NetRAID: Logical drive consistency check operation aborted
WARNING
21211
NetRAID: Logical drive inconsistencies found and corrected
WARNING
21212
NetRAID: Logical drive consistency check operation failed
CRITICAL
21213
NetRAID: Logical drive reconstruction started
INFORMATIONAL
21214
NetRAID: Logical drive reconstruction completed
INFORMATIONAL
21215
NetRAID: Logical drive reconstruction failed
CRITICAL
21216
NetRAID: Physical drive predictive failure event occurred
CRITICAL
21217
NetRAID: Physical drive predictive failure event occurred
WARNING
21218
NetRAID: Abnormal end to SCSI operation
INFORMATIONAL
21219
NetRAID: New drive inserted
INFORMATIONAL
21220
NetRAID: Backup battery module is missing or disconnected
WARNING
21221
NetRAID: Backup battery module voltage is Low
WARNING
21222
NetRAID: Backup battery module temperature is high
WARNING
21232
HP Disk Array: Write cache error
CRITICAL
21233
HP Disk Array: Logical drive critical
WARNING
21234
HP Disk Array: Logical drive not available
CRITICAL
21235
HP Disk Array: Hot spare disk failed
WARNING
21236
HP Disk Array: Hot spare replacement succeeded
INFORMATIONAL
21237
HP Disk Array: Hard disk failure
WARNING
21238
HP Disk Array: SCSI bus parity error threshold exceeded
WARNING
21239
HP Disk Array: Bad sector threshold exceeded
WARNING
21240
HP Disk Array: Disk array controller hardware error threshold
exceeded
WARNING
21241
HP Disk Array: Miscellaneous error threshold exceeded
WARNING
21242
HP Disk Array: Time to replace disk array controller
INFORMATIONAL
21301
The installed LAN adapter no longer matches the configuration
information stored about it.
WARNING
21320
The LAN adapter has detected a number of receive errors higher than
the threshold level.
WARNING
21321
The LAN adapter has detected a number of transmit errors higher
than the threshold level.
WARNING
21322
The LAN adapter installed in the server has reset itself.
CRITICAL
21323
The LAN adapter has detected a network protocol problem.
WARNING
21324
The LAN adapter has detected a packet length error.
WARNING
21325
The LAN adapter has detected a number of packet length errors
higher than threshold level.
WARNING