HP Server tc3100 hp server remote management card user guide - Page 75

FCArray: Miscellaneous error.

Page 75 highlights

Appendix A Pager Code 21902 21903 21904 21905 21906 21907 21908 21909 21910 21911 21912 21913 21914 21915 21916 21917 21918 21919 21920 21921 21922 21923 21924 21925 21926 21927 21928 21929 21930 21931 21932 21933 21934 21935 21936 Server Event FCArray: Hard disk error found. FCArray: Hard disk PFA condition found, drive may fail. FCArray: An automatic rebuild has started. FCArray: A manual rebuild has started. FCArray: Rebuild completed. FCArray: Rebuild cancelled. FCArray: Rebuild stopped with errors. FCArray: Rebuild failed due to new physical device. FCArray: Rebuild failed due to logical device failure. FCArray: A physical device failed. FCArray: A physical device was found. FCArray: A physical device is gone. FCArray: A physical device is unconfigured. FCArray: Expand capacity started. FCArray: Expand capacity finished. FCArray: Expand capacity failed. FCArray:Command to physical device timed out. FCArray:Physical device command aborted. FCArray:Command was retried. FCArray:Parity error. FCArray:Soft error. FCArray: Miscellaneous error. FCArray: Physical device reset. FCArray: A physical device became and active spare. FCArray: A physical device became a warm spare. FCArray: Request sense data present. FCArray: Consistency check started. FCArray: Consistency check completed with no errors. FCArray: Consistency check cancelled. FCArray: Consistency check completed with an error. FCArray: Consistency check failed due to logical device. FCArray: Consistency check failed due to physical device. FCArray: Logical device became offline. FCArray: Logical device became critical. FCArray: Logical device became online. Event Codes Severity CRITICAL WARNING INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL CRITICAL CRITICAL CRITICAL CRITICAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL CRITICAL CRITICAL CRITICAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL WARNING CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL INFORMATIONAL 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

Appendix A
Event Codes
Pager
Code
Server Event
Severity
21902
FCArray: Hard disk error found.
CRITICAL
21903
FCArray: Hard disk PFA condition found, drive may fail.
WARNING
21904
FCArray: An automatic rebuild has started.
INFORMATIONAL
21905
FCArray: A manual rebuild has started.
INFORMATIONAL
21906
FCArray: Rebuild completed.
INFORMATIONAL
21907
FCArray: Rebuild cancelled.
INFORMATIONAL
21908
FCArray: Rebuild stopped with errors.
CRITICAL
21909
FCArray: Rebuild failed due to new physical device.
CRITICAL
21910
FCArray: Rebuild failed due to logical device failure.
CRITICAL
21911
FCArray: A physical device failed.
CRITICAL
21912
FCArray: A physical device was found.
INFORMATIONAL
21913
FCArray: A physical device is gone.
INFORMATIONAL
21914
FCArray: A physical device is unconfigured.
INFORMATIONAL
21915
FCArray: Expand capacity started.
INFORMATIONAL
21916
FCArray: Expand capacity finished.
INFORMATIONAL
21917
FCArray: Expand capacity failed.
CRITICAL
21918
FCArray:Command to physical device timed out.
CRITICAL
21919
FCArray:Physical device command aborted.
CRITICAL
21920
FCArray:Command was retried.
INFORMATIONAL
21921
FCArray:Parity error.
INFORMATIONAL
21922
FCArray:Soft error.
INFORMATIONAL
21923
FCArray: Miscellaneous error.
INFORMATIONAL
21924
FCArray: Physical device reset.
INFORMATIONAL
21925
FCArray: A physical device became and active spare.
INFORMATIONAL
21926
FCArray: A physical device became a warm spare.
INFORMATIONAL
21927
FCArray: Request sense data present.
INFORMATIONAL
21928
FCArray: Consistency check started.
INFORMATIONAL
21929
FCArray: Consistency check completed with no errors.
INFORMATIONAL
21930
FCArray: Consistency check cancelled.
WARNING
21931
FCArray: Consistency check completed with an error.
CRITICAL
21932
FCArray: Consistency check failed due to logical device.
CRITICAL
21933
FCArray: Consistency check failed due to physical device.
CRITICAL
21934
FCArray: Logical device became offline.
CRITICAL
21935
FCArray: Logical device became critical.
CRITICAL
21936
FCArray: Logical device became online.
INFORMATIONAL
69