HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 I - Page 106
Download the firmware, using either of the following command options
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
2. Enter the slotShow command. The command output should show the new CP card as enabled. swDir:admin> slotShow Slot Blade Type ID Status 1 SW BLADE 4 FAULTY 2 SW BLADE 4 DISABLED 3 SW BLADE 4 ENABLED 4 SW BLADE 4 DIAG RUNNING POST2 5 CP BLADE 5 ENABLED 6 CP BLADE 5 ENABLED 7 UNKNOWN VACANT 8 SW BLADE 4 DIAG RUNNING POST1 9 SW BLADE 4 INSERTED, NOT POWERED ON 10 UNKNOWN VACANT swDir:admin> 3. Determine the firmware version by entering the firmwareShow command. swDir:admin> firmwareshow Primary partition: v4.2.0meteor_pit_02_031204_0722 Secondary Partition: v4.2.0meteor_pit_02_031204_0722 swDir:admin> 4. If the firmware version of the replacement card does not match that of the active CP card, bring the replacement card to the same firmware level as the active card. Check with the switch supplier for supported versions. Download the firmware, using either of the following command options: • firmwareDownload to download the firmware to both CP cards at the same time. Enter all requested information and choose the reboot option. • firmwareDownload -s to download the firmware to only one of the CP cards. Enter all requested information and choose the reboot option. 106 Installing FRUs