HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 I - Page 66
Table 7 16-port card LED patterns, port card LED patterns
![]() |
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Table 7 16-port card LED patterns LED location/ Color purpose Status Recommended action Power Steady green Port card is receiving power. No action required. No light (LED is off) Port card is not receiving Ensure card is firmly seated and power. has power. Status No light (LED is off) Port card is either Verify that the power LED is on. healthy or does not have power. Steady yellow Port card is faulty. Ensure card is firmly seated and check status with slotShow command. If LED remains yellow, consult switch supplier. Slow-flashing yellow (on Port card is not seated 2 seconds; then off 2 correctly or is faulty. seconds) Pull card out and reseat it. If LED continues to flash, replace card. Fast-flashing yellow (on 1/2 second; then off 1/2 second) Environmental range was exceeded. Check for out-of-bounds environmental condition and correct it. Port Speed (upper LED adjacent to each port) No light (LED is off) Port is either set to 1 Gb/s mode, or it does not have incoming power. Verify that the power LED is on. Use portCfgSpeed command to change mode. Steady green Port is set to 2 Gb/s mode. No action required. 66 Operating the switch
![](/manual_guide/products/hewlettpackard-storageworks-2128-hp-storageworks-core-switch-264-san-director-2128-installation-guide-aarvuscte-2005-46fb4cd/66.png)