HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 I - Page 116

Table 16 Data stored on the WWN card, Table 17 Messages that might indicate a WWN card failure

Page 116 highlights

2. Check the WWN card status using the commands listed in Table 16. Difficulty retrieving or modifying this data could indicate a WWN card failure. Table 16 Data stored on the WWN card Data Related commands WWN values wwn, chassisShow Data about the chassis and WWN card chassisShow Ethernet and Fibre Channel IP address information for the CP cards ipAddrShow, ipAddrSet History log information historyShow, historyLastShow Name of switch switchName 3. If the error log or serial console display error messages that indicate problems with the WWN unit (see Table 17), the WWN card might have failed. WWN units correspond to information specific to the WWN card and are displayed by the chassisShow command. For additional information about this command, refer to the HP StorageWorks command reference guide for the Fabric OS version running on your switch. Table 17 Messages that might indicate a WWN card failure Type of message Sample error message WWN unit fails its FRU header access. 0x24c (fabos): Switch: switchname, error EM-I2C_TIMEOUT, 2, WWN I2C timed out: state 0x4 WWN unit is being faulted. 0x24c (fabos): Switch: switchname, Critical EM-WWN_UNKNOWN, 1, Unknown WWN is being faulted WWN unit is not present or 0x24c (fabos): Switch: switchname, Error is not accessible. EM-WWN_ABSENT, 2, WWN not present Writing to the FRU history log 0x24c (fabos): Switch: switchname, Error (hilSetFruHistory) has EM-HIL_FAIL, 2, HIL Error: hilSetFruHistory failed. failed, rc=-3 for SLOT 3 116 Installing FRUs

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Installing FRUs
116
2.
Check the WWN card status using the commands listed in
Table 16
. Difficulty retrieving or
modifying this data could indicate a WWN card failure.
3.
If the error log or serial console display error messages that indicate problems with the
WWN unit (see
Table 17
), the WWN card might have failed.
WWN units correspond to information specific to the WWN card and are displayed by
the
chassisShow
command. For additional information about this command, refer to the
HP StorageWorks command reference guide
for the Fabric OS version running on
your switch.
Table 16
Data stored on the WWN card
Data
Related commands
WWN values
wwn
,
chassisShow
Data about the chassis and WWN card
chassisShow
Ethernet and Fibre Channel IP address
information for the CP cards
ipAddrShow
,
ipAddrSet
History log information
historyShow
,
historyLastShow
Name of switch
switchName
Table 17
Messages that might indicate a WWN card failure
Type of message
Sample error message
WWN unit fails its FRU
header access.
0x24c (fabos): Switch:
switchname
, error
EM-I2C_TIMEOUT, 2, WWN I2C timed out: state
0x4
WWN unit is being faulted.
0x24c (fabos): Switch:
switchname
, Critical
EM-WWN_UNKNOWN, 1, Unknown WWN is being
faulted
WWN unit is not present or
is not accessible.
0x24c (fabos): Switch:
switchname
, Error
EM-WWN_ABSENT, 2, WWN not present
Writing to the FRU history log
(
hilSetFruHistory
) has
failed.
0x24c (fabos): Switch:
switchname
, Error
EM-HIL_FAIL, 2, HIL Error: hilSetFruHistory