HP StorageWorks 2/64 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 I - Page 28

Installation overview, Selecting an operating location

Page 28 highlights

Table 4 Carton contents checklist (continued) Item Summary 3 14U Rack Mount Kit Rails, includes the following: • Left rack mount shelf bracket, (1); Right rack mount shelf bracket (1) • Left upper rack mount bracket assembly includes: Left upper rack mount bracket (flat); left upper rack mount bracket (L-shaped); screw (torque to 32 inch-pounds) • Right upper rack mount bracket assembly includes: right upper rack mount bracket (flat); right upper rack mount bracket (L-shaped); screw (torque to 32 inch-pounds) • M5 Tinnermans (0590-2318) and M5 Torx screws (0515-0671) are required rack mount kit hardware. 4 14U Rack Mount Kit hardware: • #10-32 x 5/16 Phillips flathead screws (8); #10-32 x 5/16 Phillips panhead screws with washers (4) • For use with an HP 42U rack (or racks with square holes): #10-32 x 5/16 retainer nuts; #1/4-20 x 0.500 Phillips panhead screws with glue (16); 0.375-inch square washers (16) • For use with rack with round holes: #10-32 clip nut (package of 20, only 4 required); #1/4-20 x 1/2 inch Phillips panhead screws with lockhead washers (16) Installation overview You can install the Core Switch 2/64 or SAN Director2/128 in one of the following ways: • As a stand-alone unit on a stable table or lab workbench • In a rack using the 14U Rack Mount Kit supplied with the switch Selecting an operating location Verify that the switch location meets the following requirements: • Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate. • Air flow of at least 350 cubic feet per minute, available in the immediate vicinity of the Core Switch 2/64 or SAN Director 2/128. • If you are installing the switch in an HP rack: 28 Installing and configuring the switch

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Installing and configuring the switch
28
Installation overview
You can install the Core Switch 2/64 or SAN Director2/128 in one of the following ways:
As a stand-alone unit on a stable table or lab workbench
In a rack using the 14U Rack Mount Kit supplied with the switch
Selecting an operating location
Verify that the switch location meets the following requirements:
Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on
the switch nameplate.
Air flow of at least 350 cubic feet per minute, available in the immediate vicinity of the
Core Switch 2/64 or SAN Director 2/128.
If you are installing the switch in an HP rack:
3
14U Rack Mount Kit Rails, includes the following:
Left rack mount shelf bracket, (1); Right rack mount shelf bracket (1)
Left upper rack mount bracket assembly includes: Left upper rack mount bracket (flat);
left upper rack mount bracket (L-shaped); screw (torque to 32 inch-pounds)
Right upper rack mount bracket assembly includes: right upper rack mount bracket
(flat); right upper rack mount bracket (L-shaped); screw (torque to 32 inch-pounds)
M5 Tinnermans (0590-2318) and M5 Torx screws (0515-0671) are required rack
mount kit hardware.
4
14U Rack Mount Kit hardware:
#10-32 x 5/16 Phillips flathead screws (8); #10-32 x 5/16 Phillips panhead screws
with washers (4)
For use with an HP 42U rack (or racks with square holes): #10-32 x 5/16 retainer nuts;
#1/4-20 x 0.500 Phillips panhead screws with glue (16); 0.375-inch square washers
(16)
For use with rack with round holes: #10-32 clip nut (package of 20, only 4 required);
#1/4-20 x 1/2 inch Phillips panhead screws with lockhead washers (16)
Table 4
Carton contents checklist (continued)
Item
Summary