Step 7. Change the controller default host port behavior
View all HP StorageWorks 7410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Step 7. Change the controller default host port behavior Note It is recommended that the default controller port behavior be set for the operating system of the host running CommandView SDM. This ensures that the management station will still function if the host port behavior table in the array is corrupted or lost. 1 To change the host port behavior for Controller 1 enter the following command, selecting the appropriate behavior value: mgr -os -c 1 2 To change the host port behavior for Controller 2, enter the following command, selecting the appropriate behavior value: mgr -os -c 2 To view the current host port behavior setting for controller 1 or controller 2, enter the following commands: dsp -c 1 dsp -c 2 Step 8. Change the controller port data rate to 2 Gbit/sec (VA 7110/7400/7410 Only) 1 To change the port data rate to 2 Gbit/sec for controller 1, enter: mgr -S 2 -c 1 2 When prompted to reset, enter no. 3 To change the port data rate for controller 2, enter: mgr -S 2 -c 2 4 When prompted to reset, enter no if additional settings must be changed. If all changes have been made, enter yes to reset the array. Virtual Array Installation Guide 25