HP StorageWorks 7410 HP StorageWorks Virtual Array va 7000 family - Installati - Page 26

Step 9. Change the controller port topology, Step 11. Change the RAID operating level of the array

Page 26 highlights

Step 9. Change the controller port topology 1 To change the port topology for controller 1 enter the following command, selecting 2 for Public Loop or 4 for Direct Fabric Attach: mgr -t < 2 | 4 > -c 1 2 When prompted to reset, enter no. 3 To change the port topology for controller 2 enter the following command, using the same topology value used for controller 1: mgr -t < 2 | 4 > -c 2 4 When prompted to reset, enter no if additional settings must be changed. If all changes have been made, enter yes to reset the array. Step 10. Change the controller loop ID 1 To change the loop ID for Controller 1, enter: mgr -L loop_ID -c 1 where loop_ID is a value from 1 to 125 2 When prompted to reset, enter no. 3 To change the loop ID for Controller 2, enter: mgr -L loop_ID -c 2 4 When prompted to reset, enter no if additional settings must be changed. If all changes have been made, enter yes to reset the array. Step 11. Change the RAID operating level of the array If the customer wants to operate the array in RAID 1+0 mode rather than AutoRAID, change the level as follows: 1 To change the RAID level to RAID 1+0, enter: mgr -B raid1 2 When prompted to reset, enter yes to reset the array. 26 Virtual Array Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

26
Virtual Array Installation Guide
Step 9. Change the controller port topology
1
To change the port topology for controller 1 enter the following command,
selecting
2
for Public Loop or
4
for
Direct Fabric Attach:
mgr -t
<
2
|
4
>
-c 1
2
When prompted to reset, enter
no
.
3
To change the port topology for controller 2 enter the following command,
using the same topology value used for controller 1:
mgr -t
<
2
|
4
>
-c 2
4
When prompted to reset, enter
no
if additional settings must be changed. If
all changes have been made, enter
yes
to reset the array
.
Step 10. Change the controller loop ID
1
To change the loop ID for Controller 1, enter:
mgr -L
loop_ID
-c 1
where
loop_ID
is a value from 1 to 125
2
When prompted to reset, enter
no
.
3
To change the loop ID for Controller 2, enter:
mgr -L
loop_ID
-c 2
4
When prompted to reset, enter
no
if additional settings must be changed. If
all changes have been made, enter
yes
to reset the array
.
Step 11. Change the RAID operating level of the array
If the customer wants to operate the array in RAID 1+0 mode rather than
AutoRAID, change the level as follows:
1
To change the RAID level to RAID 1+0, enter:
mgr -B raid1
2
When prompted to reset, enter
yes
to reset the array
.