Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 10

Connecting AlarmNet 7845GSM / 7845i-GSM, Connecting AlarmNet 7845i-ENT/7845i/7847i-E

Page 10 highlights

LYNXR-2 Series Installation and Setup Guide Connecting/Configuring Communication Modules AlarmNet 7845GSM, 7845i-GSM*, 7845i-ENT, 7845i or 7847i-E* Communications Device  The 7845i-ENT and 7845i cannot be used for installations requiring 24-hour standby. 1. Connect the 4-wire communications cable to the LRR/IP Communications port on the LYNXR-2 Series. 2. Connect the four wires to the specific Communications device as shown in the accompanying figures. 3. If you are installing a 7845GSM or 7845i-GSM you must also install a jumper between terminals 2 and 3 on the communications device. 4. Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet connection, if applicable. UL AlarmNet 7845GSM and 7845i-GSM modules have not been evaluated by UL. * When available 7845GSM / TB1 7845i-GSM 1 2 ECP (+) VOLTAGE INPUT 34 GND 4 Z1/Z2 OR DATA IN 5 Z3 OR DATA OUT 6 CONTROL PANEL RED BLK YEL GRN GRN BLK RED YEL LRR/IP COMMUNICATIONS PORT DATA IN GND +12 VDC NC DATA OUT 4-WIRE CABLE (N4632-4) LYNX STANDARD CAPACITY BATTERY (OPTIONAL) REQUIRED FOR LYNX SUPER HIGH CAPACITY 24-HR BACKUP BATTERY Connecting AlarmNet 7845GSM / 7845i-GSM 09012-018-V0 7845i-ENT / 7845i CONTROL PANEL TB 1 (+) VOLTAGE INPUT RED GND BLK DATA OUT GRN YEL DATA IN GRN BLK RED YEL LRR/IP COMMUNICATIONS PORT DATA IN GND +12 VDC NC DATA OUT 4-WIRE CABLE (N4632-4) LYNX STANDARD CAPACITY BATTERY Connecting AlarmNet 7845i-ENT/7845i/7847i-E* 09012-019-V0 - 10 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

LYNXR-2 Series Installation and Setup Guide
- 10 -
Connecting/Configuring Communication Modules
AlarmNet 7845GSM, 7845i-GSM*, 7845i-ENT, 7845i or 7847i-E* Communications Device
The 7845i-ENT and 7845i cannot be used for installations requiring 24-hour standby.
1. Connect the 4-wire communications cable to the LRR/IP Communications port on the LYNXR-2 Series.
2. Connect the four wires to the specific Communications device as shown in the accompanying figures.
3.
If you are installing a 7845GSM or 7845i-GSM you must also install a jumper between terminals 2 and 3 on the
communications device.
4.
Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet
connection, if applicable.
UL
UL
UL
UL
AlarmNet 7845GSM and 7845i-GSM modules have not been evaluated by UL.
* When available
7845GSM /
7845i-GSM
LYNX
SUPER HIGH
CAPACITY
BATTERY
(OPTIONAL)
REQUIRED FOR
24-HR BACKUP
09012-018-V0
GND
Z3 OR DATA OUT
Z1/Z2 OR DATA IN
ECP (+) VOLTAGE INPUT
RED
BLK
GRN
YEL
RED
BLK
GRN
YEL
4
5
6
3
5
4
4-WIRE CABLE (N4632-4)
1
2
TB1
LRR/IP COMMUNICATIONS PORT
CONTROL PANEL
NC
+12 VDC
GND
DATA IN
DATA OUT
LYNX
STANDARD
CAPACITY
BATTERY
Connecting AlarmNet 7845GSM / 7845i-GSM
7845i-ENT / 7845i
09012-019-V0
GND
DATA IN
DATA OUT
(+) VOLTAGE INPUT
TB 1
RED
BLK
GRN
YEL
RED
BLK
GRN
YEL
4-WIRE CABLE (N4632-4)
LRR/IP COMMUNICATIONS PORT
CONTROL PANEL
NC
+12 VDC
GND
DATA IN
DATA OUT
LYNX
STANDARD
CAPACITY
BATTERY
Connecting AlarmNet 7845i-ENT/7845i/7847i-E*