Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 24

Field, Power Up In Previous State, Cross Zone Timer, DIALER PROGRAMMING, Fields, PABX Access Code/ - 3 phone how

Page 24 highlights

LYNXR-2 Series Installation and Setup Guide Data Field Descriptions Field ✻39: Field *39 is used to program different features in the LYNXR-2 and LYNXR-2SIA controls. Please be sure that you use the correct field for the control being installed. ✻39 Power Up In Previous State Note: This field applies only to the LYNXR-2 control. LYNXR-2 SELECTIONS 0 = always power up in a disarmed state 1 = assume the system status prior to power-down ✻39 Cross Zone Timer Note: This field applies only to the LYNXR-2SIA control. LYNXR-2SIA SELECTIONS Value 0 = 1 = 2 = 3 = 4 = 5 = 6 = 7 = 8 = 9 = # + 10 = # + 11 = # + 12 = # + 13 = # + 14 = # + 15 = Time Window No Cross Zoning 15 seconds 30 seconds 45 seconds 60 seconds 1 minute, 15 seconds 1 minute, 30 seconds 1 minute, 45 seconds 2 minutes 2 minute, 15 seconds 2 minute, 30 seconds 2 minute, 45 seconds 3 minutes 3 minute, 15 seconds 3 minute, 30 seconds 3 minute, 45 seconds When the system powers up armed, an alarm will occur 1 minute after arming if a zone is faulted, and any bypassed zones will be unbypassed. Note: If the previous state was armed AWAY or STAY, the system will not respond to sensor changes for 1 minute, which allows time for sensors such as PIRs to stabilize. UL installations: must be 1 (power up in previous state) Sets the maximum amount of time in which two cross zones must be tripped in an armed system to send an alarm message to the Central Station. If only one cross zone is tripped during this time, a trouble message (CID code 380) for that zone is sent to the Central Station. Program Zone list 2 (using *81 Zone List Menu Mode) with the two zones that are to be cross zoned. Notes: (1) If option ✻39 is set to "0" (no cross zoning) then Zone List 2 can be used for other purposes. (2) Cross zoning will be disabled during entry and exit delays, if there is already an alarm in the system, if one or both of the 2 cross zones is bypassed. If one of the 2 cross zones faults and remains faulted after the cross zone time interval, the second cross zone can go into alarm immediately, even after the cross zone time. This is to detect scenarios involving multiple break-ins of a premises. UL This option is not for use in UL installations. DIALER PROGRAMMING (✻40-✻50) Fields ✻40, ✻41, ✻42: Enter up to the number of digits shown. Enter 0-9, # + 11 for '*'; # + 12 for '#'; # + 13 for a pause (2 seconds). Field *40 is used to program different features in the LYNXR-2 and LYNXR-2SIA controls. Please be sure that you use the correct field for the control being installed. Notes: Whenever AAV is used, primary (field ✻41) and secondary (field ✻42) phone numbers should be preceded with the call waiting disable command. Otherwise, there is the possibility of connection of the third party to LYNXR-2 Series during AAV mode. The PABX phone number entered in field ✻40 is not dialed on GSM/IP (Digital Communication with AAV). However, it is used for dialing on Telco Line. ✻40 PABX Access Code/Call Waiting Disable LYNXR-2 SELECTIONS PABX Access Code Enter up to 6 digits if PABX is needed to access an outside line. LYNXR-2SIA SELECTIONS PABX Access Code/Call Waiting Disable Enter up to 6 digits if PABX is needed to access an outside line. or Enter"# + 11 + 7 + 0" to program the touch-tone sequence "*70" and cancel call waiting. If fewer than 6 digits need to be entered, exit by pressing [✻]. To clear entries from field, press ✻40✻. LYNXR-2SIA ONLY Call Waiting: If the subscriber's phone service has "call waiting" (and is not using PABX), enter the touch-tone sequence"*70" (or similar depending on the phone service). By programming "# + 11 + 7 + 0" as the PABX entry to disable "call waiting" during control panel calls. You must also enable the Call Waiting Cancel option in field *47. If the subscriber does not have "call waiting" and is not using PABX, make no entry in this field. Important Note: If Call Wait Cancel is disabled in Field ✻47, and Call Wait Disable command is entered in Field ✻40, this will prevent successful communication to the central station when used on a non-call waiting line. Note: PABX number and operation of the control panel with a PBX system cannot be used if the Call Waiting Cancel Disable option has been enabled in Field ✻47. - 24 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

LYNXR-2 Series Installation and Setup Guide
- 24 -
Data Field Descriptions
Field
39:
Field *39 is used to program different features in the LYNXR-2 and LYNXR-2SIA controls.
Please be sure that you use the correct field for the control being installed.
39
Power Up In Previous State
Note:
This field applies only to the LYNXR-2 control.
LYNXR-2 SELECTIONS
0 = always power up in a disarmed state
1 = assume the system status prior to power-down
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted, and any bypassed zones will be
unbypassed.
Note:
If the previous state was armed
AWAY
or
STAY
, the system will
not respond to sensor changes for 1 minute, which allows time for
sensors such as PIRs to stabilize.
UL installations:
must be 1 (power up in previous state)
39
Cross Zone Timer
Note:
This field applies only to the LYNXR-2SIA
control.
LYNXR-2SIA SELECTIONS
Value
Time Window
0 =
No Cross Zoning
1 =
15 seconds
2 =
30 seconds
3 =
45 seconds
4 =
60 seconds
5 =
1 minute, 15 seconds
6 =
1 minute, 30 seconds
7 =
1 minute, 45 seconds
8 =
2 minutes
9 =
2 minute, 15 seconds
# + 10 =
2 minute, 30 seconds
# + 11 =
2 minute, 45 seconds
# + 12 =
3 minutes
# + 13 =
3 minute, 15 seconds
# + 14 =
3 minute, 30 seconds
# + 15 =
3 minute, 45 seconds
Sets the maximum amount of time in which two cross zones
must be tripped in an armed system to send an alarm message
to the Central Station. If only one cross zone is tripped during
this time, a trouble message (CID code 380) for that zone is
sent to the Central Station. Program Zone list 2 (using *81
Zone List Menu Mode) with the two zones that are to be cross
zoned.
Notes
: (1) If option
39 is set to “0” (no cross zoning) then Zone List 2
can be used for other purposes.
(2) Cross zoning will be disabled during entry and exit delays, if
there is already an alarm in the system, if one or both of the 2
cross zones is bypassed.
If one of the 2 cross zones faults and remains faulted after the
cross zone time interval, the second cross zone can go into
alarm immediately, even after the cross zone time. This is to
detect scenarios involving multiple break-ins of a premises.
UL
This option is not for use in UL installations.
DIALER PROGRAMMING (
40
50)
Fields
40,
41,
42:
Enter up to the number of digits shown. Enter 0
9, # + 11 for
*
; # + 12 for
#
; # + 13
for a pause (2 seconds). Field *40 is used to program different features in the LYNXR-2 and LYNXR-2SIA
controls. Please be sure that you use the correct field for the control being installed.
Notes:
Whenever AAV is used, primary (field
41) and secondary (field
42) phone numbers should be preceded with the
call waiting disable command.
Otherwise, there is the possibility of connection of the third party to LYNXR-2 Series
during AAV mode. The PABX phone number entered in field
40 is not dialed on GSM/IP (Digital Communication
with AAV). However, it is used for dialing on Telco Line.
40
PABX Access Code/Call Waiting
Disable
LYNXR-2 SELECTIONS
PABX Access Code
Enter up to 6 digits if PABX is needed to access an outside
line.
LYNXR-2SIA SELECTIONS
PABX Access Code/Call Waiting Disable
Enter up to 6 digits if PABX is needed to access an outside
line.
or
Enter“# + 11 + 7 + 0” to program the touch-tone sequence
“*70” and cancel call waiting.
If fewer than 6 digits need to be entered, exit by pressing [
].
To clear entries from field, press
40
.
LYNXR-2SIA ONLY
Call Waiting:
If the subscriber
s phone service has
call
waiting
(and is not using PABX), enter the touch-tone
sequence
*70
(or similar depending on the phone service). By
programming
# + 11 + 7 + 0
as the PABX entry to disable
call waiting
during control panel calls.
You must also enable
the Call Waiting Cancel option in field *47.
If the subscriber does not have
call waiting
and is not using
PABX, make no entry in this field.
Important Note:
If Call Wait Cancel is disabled in Field
47, and Call Wait
Disable command is entered in Field
40, this will
prevent successful communication to the central station
when used on a non-call
waiting line.
Note:
PABX number and operation of the control
panel with a PBX
system cannot be used if the Call Waiting Cancel Disable option
has been enabled in Field
47.