Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 44

Start Zone Type, Stop Zone List, Stop Zone Type

Page 44 highlights

LYNXR-2 Series Installation and Setup Guide ✻80 Device Programming Menu Mode E zt Start Zone Type 01-58 = zone type to start this device action (select only those that are applicable 00 = zone type not used for this device [✻] = continue [#] = return to previous prompt F zl Stop Zone List 1-3 = zone list to stop this device action 0 = zone list not used [✻] = continue [#] = return to previous prompt 1A zt Stop Zone Type 01-58 = zone type to stop this device action (select only those that are applicable 00 = zone type not used for this device [✻] = continue [#] = return to previous prompt If a zone type or system operation will be used to start the device action, enter the appropriate 2-digit code for the device being programmed (see table that follows). Choices for zone types 00 = Not Used 07 = 24 Hr Audible 01 = Entry/Exit #1 08 = 24 Hr Aux 02 = Entry/Exit #2 09 = Fire without verification 03 = Perimeter 10 = Interior w/Delay 04 = Interior Follower 14 = Carbon Monoxide 05 = Trouble Day/Alarm Night 16 = Fire with verification 06 = 24 Hr Silent 24 = Silent Burglary Choices for system operation 20 = Arming-Stay 38 = Chime 21 = Arming-Away 52 = Kissoff 22 = Disarm. (Code + OFF) 39 = Any Fire Alarm 31 = End of Exit Time 40 = Bypassing 32 = Start of Entry Time 42 = System Battery Low 33 = Any Alarm (except ZT 08, 43 = Communications Failure 09, 14 or 16) 36 = At Bell Timeout** 58 = Duress ** Or at Disarming (which ever occurs earlier) SIA ZT 16 must be used in SIA fire applications. If a zone list will be used to STOP, or restore, the device action, enter the zone list number 1, 2, or 3 (to be programmed in ✻81 mode). If not used, enter "0". If a zone type or system operation will be used to STOP the device action, enter the appropriate 2-digit code (see the "ZT" choices listed above). If not, enter 00. The display then returns to the DEVICE NUMBER prompt (A) so that you can enter the next device number to be programmed, or enter [0][0] to end device programming - 44 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

LYNXR-2 Series Installation and Setup Guide
- 44 -
80 Device Programming Menu Mode
E
zt
Start Zone Type
01-58 = zone type to start this device action
(select only those that are applicable
00 = zone type not used for this device
[
] = continue
[#] = return to previous prompt
If a zone type or system operation will be used to start the device action, enter the
appropriate 2-digit code for the device being programmed (see table that follows).
Choices for zone types
00 = Not Used
07 = 24 Hr Audible
01 = Entry/Exit #1
08 = 24 Hr Aux
02 = Entry/Exit #2
09 = Fire without verification
03 = Perimeter
10 = Interior w/Delay
04 = Interior Follower
14 = Carbon Monoxide
05 = Trouble Day/Alarm Night
16 = Fire with verification
06 = 24 Hr Silent
24 = Silent Burglary
Choices for system operation
20 = Arming
Stay
38 = Chime
21 = Arming
Away
52 = Kissoff
22 = Disarm. (Code + OFF)
39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time
42 = System Battery Low
33 = Any Alarm (except ZT 08,
09, 14 or 16)
43 = Communications Failure
36 = At Bell Timeout**
58 = Duress
** Or at Disarming (which ever occurs earlier)
SIA
ZT 16 must be used in SIA fire applications.
F
zl
Stop Zone List
1-3 = zone list to stop this device action
0 = zone list not used
[
] = continue
[#] = return to previous prompt
If a zone list will be used to STOP, or restore, the device action, enter the zone list
number 1, 2, or 3 (to be programmed in
81 mode). If not used, enter
0
.
1A
zt
Stop Zone Type
01-58 = zone type to stop this device action
(select only those that are applicable
00 = zone type not used for this device
[
] = continue
[#] = return to previous prompt
If a zone type or system operation will be used to STOP the device action, enter the
appropriate 2-digit code (see the "ZT" choices listed above). If not, enter 00. The
display then returns to the DEVICE NUMBER prompt (A) so that you can enter the
next device number to be programmed, or enter [0][0] to end device programming