Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 87
Lynxr-2 Series Summary Of Connections
![]() |
UPC - 781410916135
View all Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
DATA IN GND DATA OUT POWERLINE CARRIER DEVICES Notes: Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police emergency number. The System must be checked by a qualified technician once every three years. - 87 - UL INSTALLATIONS THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAUGE WARNING: TO PREVENT RISK OF SHOCK DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT. LRR/IP COMMUNICATIONS PORT POWER SHUTDOWN NOTE: AT 6.0VDC THE SYSTEM WILL NOT OPERATE. TO HANDSET PHONE LINE INCOMING PHONE LINE EARTH GROUND UL NOTE THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAUGE PHONE ALL OUTPUT CIRCUITS ARE POWER LIMITED. FUTURE USE GND SOUNDERS LOCAL SOUNDER DISABLE SHUNT REMOVE TO DISABLE PLCD AC RJ11 8 POS JACK 1 2 3 4 56 7 8 9 10 11 12 13 14 15 16 TIP RINNGG TIPP RIINNGG (( )) DDAATTAA SSYYNNCC OOUUTT IINN EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL. FCC ID: CFS8DLLYNXREN-6 (LYNXR-2 SERIES) COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No. 5GBUSA-25623-AL-E RINGER EQUIVALENCE: 0.6B NOTE USE ONLY THE K10145X10 OR K10145CN CLASS 2 TRANSFORMERS PROVIDED GSML/GSMVL COMMUNICATIONS PORT STANDARD HIGH-CAPACITY BATTERY CONNECTOR SUPER HIGH-CAPACITY BATTERY CONNECTOR THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2 (NATIONAL FIRE PROTECTION ASSOC., BATTERY MARCH PARK, QUINCY, MA 02269). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. LYNXR-2 SERIES ALSO COMPLIES WITH THE FOLLOWING: CANADIAN STANDARDS ASSOCIATION (CSA) C22.1, CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS. INCOMING TELEPHONE LINE PREMISES TELEPHONE FUTURE USE PIEZO BELL 6-14VDC 30mA max. 6-14VDC 120mA max. (e.g. WAVE2EX) TO 24HR 110VAC UNSWITCHED OUTLET AC AC SYNC COM EARTH GROUND THE LYNXR-2 SERIES CONTROLS ARE COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS: P/N LYNXRCHKIT-SC P/N LYNXRCHKIT-HC P/N LYNXRCHKIT-SHA REPLACE EVERY FOUR YEARS WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM GND SOUNDERS PLCD DATA K10145X10 PLUG-IN TRANSFORMER 9VAC, 25VA X10 ONLY CONNECTIONS AC FOR CANADIAN INSTALLATIONS WARNING THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CIRCUIT (ZONE) 02 - 25 ZT16 CONTROL UNIT DELAY-SEC 30 seconds SMOKE DETECTOR MODEL DELAY-SEC 5806 10 seconds TO 24HR 110VAC 9 13 14 15 16 UNSWITCHED OUTLET K10145CN PLUG-IN TRANSFORMER 9VAC, 25VA YELLOW BLACK RED GREEN 4-WIRE MODULAR PHONE CORD WITH FLYING LEADS 1 2 3 4 PL513 POWERLINE INTERFACE (IF USING X10 DEVICES) LYNXR-2 SERIES SUMMARY OF CONNECTIONS 07000-016-V3
![](/manual_guide/products/honeywell-lynxrpk2-wireless-selfcontained-security-syste-installation-guide-922413c/87.png)