Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste Installation Guid - Page 87

Lynxr-2 Series Summary Of Connections

Page 87 highlights

DATA IN GND DATA OUT POWERLINE CARRIER DEVICES Notes: Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police emergency number. The System must be checked by a qualified technician once every three years. - 87 - UL INSTALLATIONS THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAUGE WARNING: TO PREVENT RISK OF SHOCK DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT. LRR/IP COMMUNICATIONS PORT POWER SHUTDOWN NOTE: AT 6.0VDC THE SYSTEM WILL NOT OPERATE. TO HANDSET PHONE LINE INCOMING PHONE LINE EARTH GROUND UL NOTE THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAUGE PHONE ALL OUTPUT CIRCUITS ARE POWER LIMITED. FUTURE USE GND SOUNDERS LOCAL SOUNDER DISABLE SHUNT REMOVE TO DISABLE PLCD AC RJ11 8 POS JACK 1 2 3 4 56 7 8 9 10 11 12 13 14 15 16 TIP RINNGG TIPP RIINNGG (( )) DDAATTAA SSYYNNCC OOUUTT IINN EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL. FCC ID: CFS8DLLYNXREN-6 (LYNXR-2 SERIES) COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No. 5GBUSA-25623-AL-E RINGER EQUIVALENCE: 0.6B NOTE USE ONLY THE K10145X10 OR K10145CN CLASS 2 TRANSFORMERS PROVIDED GSML/GSMVL COMMUNICATIONS PORT STANDARD HIGH-CAPACITY BATTERY CONNECTOR SUPER HIGH-CAPACITY BATTERY CONNECTOR THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2 (NATIONAL FIRE PROTECTION ASSOC., BATTERY MARCH PARK, QUINCY, MA 02269). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. LYNXR-2 SERIES ALSO COMPLIES WITH THE FOLLOWING: CANADIAN STANDARDS ASSOCIATION (CSA) C22.1, CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS. INCOMING TELEPHONE LINE PREMISES TELEPHONE FUTURE USE PIEZO BELL 6-14VDC 30mA max. 6-14VDC 120mA max. (e.g. WAVE2EX) TO 24HR 110VAC UNSWITCHED OUTLET AC AC SYNC COM EARTH GROUND THE LYNXR-2 SERIES CONTROLS ARE COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS: P/N LYNXRCHKIT-SC P/N LYNXRCHKIT-HC P/N LYNXRCHKIT-SHA REPLACE EVERY FOUR YEARS WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM GND SOUNDERS PLCD DATA K10145X10 PLUG-IN TRANSFORMER 9VAC, 25VA X10 ONLY CONNECTIONS AC FOR CANADIAN INSTALLATIONS WARNING THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CIRCUIT (ZONE) 02 - 25 ZT16 CONTROL UNIT DELAY-SEC 30 seconds SMOKE DETECTOR MODEL DELAY-SEC 5806 10 seconds TO 24HR 110VAC 9 13 14 15 16 UNSWITCHED OUTLET K10145CN PLUG-IN TRANSFORMER 9VAC, 25VA YELLOW BLACK RED GREEN 4-WIRE MODULAR PHONE CORD WITH FLYING LEADS 1 2 3 4 PL513 POWERLINE INTERFACE (IF USING X10 DEVICES) LYNXR-2 SERIES SUMMARY OF CONNECTIONS 07000-016-V3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

- 87 -
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
POWER SHUTDOWN NOTE:
AT 6.0VDC THE SYSTEM WILL NOT OPERATE.
PREMISES
TELEPHONE
K10145X10 PLUG-IN
TRANSFORMER
9VAC, 25VA
EARTH
GROUND
INCOMING
TELEPHONE
LINE
TO 24HR 110VAC
UNSWITCHED
OUTLET
PIEZO
6-14VDC
120mA max.
(e.g. WAVE2EX)
6-14VDC
30mA max.
AC
AC
SYNC
COM
DATA
BELL
07000-016-V3
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE
WITH THE NATIONAL FIRE PROTECTION ASSOCIATION
STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND
NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2
(NATIONAL FIRE PROTECTION ASSOC., BATTERY MARCH
PARK, QUINCY, MA 02269). PRINTED INFORMATION
DESCRIBING PROPER INSTALLATION, EVACUATION
PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
X10 ONLY
CONNECTIONS
FCC ID: CFS8DLLYNXREN-6
(LYNXR-2 SERIES)
COMPLIES WITH FCC RULES,
PART 68 FCC REGISTRATION
No. 5GBUSA-25623-AL-E
RINGER EQUIVALENCE: 0.6B
NOTE
USE ONLY THE K10145X10
OR K10145CN CLASS 2
TRANSFORMERS
PROVIDED
LYNXR-2 SERIES SUMMARY OF CONNECTIONS
LYNXR-2 SERIES ALSO COMPLIES WITH THE FOLLOWING:
CANADIAN STANDARDS ASSOCIATION (CSA) C22.1,
CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD
FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540
INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS.
THE LYNXR-2 SERIES CONTROLS ARE
COMPATIBLE WITH THE FOLLOWING
INTEGRAL RECHARGEABLE BATTERY PACKS:
EXTERNAL SOUNDERS
AND POWERLINE
CARRIER DEVICES HAVE
NOT BEEN EVALUATED
BY UL.
FUTURE
USE
REPLACE EVERY FOUR YEARS
P/N LYNXRCHKIT-SC
P/N LYNXRCHKIT-HC
P/N LYNXRCHKIT-SHA
POWERLINE
CARRIER DEVICES
GND
DATA IN
DATA OUT
INCOMING
PHONE
LINE
TO
HANDSET
PHONE
LINE
WARNING:
TO PREVENT RISK OF
SHOCK DISCONNECT
TELEPHONE LINE
AT TELECOM JACK
BEFORE SERVICING
THIS UNIT.
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
1
2
3
4
8
6
5
11
7
10
12
15
16
13
14
PHONE
FUTURE
USE
SOUNDERS
PLCD
AC
EARTH
GROUND
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
DATA
OUT
SYNC
IN
RJ11
8
POS
JACK
9
GND
LOCAL SOUNDER
DISABLE SHUNT
REMOVE TO DISABLE
UL NOTE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAUGE
SUPER HIGH-CAPACITY
BATTERY CONNECTOR
LRR/IP
COMMUNICATIONS
PORT
GSML/GSMVL
COMMUNICATIONS
PORT
STANDARD
HIGH-CAPACITY
BATTERY CONNECTOR
UL INSTALLATIONS
THE MINIMUM WIRE
SIZE USED FOR
TELEPHONE
INSTALLATIONS
MUST BE #26 GAUGE
CIRCUIT
(ZONE)
CONTROL UNIT
DELAY-SEC
SMOKE DETECTOR
MODEL
DELAY-SEC
THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM
VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE
SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS.
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS)
SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING
DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
WARNING
5806
10 seconds
30 seconds
02 - 25
ZT16
SOUNDERS
PLCD
AC
TO 24HR 110VAC
UNSWITCHED
OUTLET
GND
1 2 3 4
BLACK
RED
YELLOW
GREEN
PL513
POWERLINE
INTERFACE
(IF USING
X10 DEVICES)
4-WIRE MODULAR PHONE
CORD WITH FLYING LEADS
K10145CN
PLUG-IN
TRANSFORMER
9VAC, 25VA
9
15
16
13
14
FOR CANADIAN INSTALLATIONS
Notes:
Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the
approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police
emergency number.
The System must be checked by a qualified technician once every three years.